Independent formula illustration · no measured data or FEA results
What is being selected?
Choose a hardening representation for the required observation and prediction range, rather than assigning a law solely from the alloy name. This chapter concerns monotonic isotropic metal hardening. It does not establish a model for polymers, foams, adhesives or cyclic loading.
Three choices should be recorded separately: hardening describes the undamaged flow stress; extrapolation extends beyond the identified range; damage introduces initiation and subsequent degradation. Extrapolation and damage can be used together. A descending specimen force can also reflect necking and changing geometry, so it is not automatically a descending constitutive stress–strain law. [S3]
Swift and Voce
Here p is equivalent plastic strain and σy is undamaged flow stress. Use the appropriate true-stress/plastic-strain convention, not engineering or total strain in place of p. [S2, S4]
| Law | Definition | Large-strain behavior | Initial flow stress |
|---|---|---|---|
| Swift | σy=K(ε0+p)^n |
No finite saturation stress for positive n | K ε0^n |
| Voce | σy=σ0+Q[1−exp(−bp)] |
Approaches σ0+Q for positive Q,b |
σ0 |
For Swift, K has stress units, while ε0 is a fitted offset and n controls the curve shape. ε0 is not automatically a measured prestrain. For a conventional positive hardening example, K>0, ε0>0 and 0<n<1 may be considered. The plastic tangent is H=nK(ε0+p)^(n−1).
For Voce, Q is the stress increase from the initial value to saturation and b controls the approach. Its plastic tangent is H=Qb exp(−bp). H is not Young’s modulus E. These derivatives and limiting behaviors follow directly from the formulas; the law definitions are documented in [S2].
A practical selection sequence
| Available evidence | Candidates to compare | Important question |
|---|---|---|
| Reliable plastic points cover the required range | A tabulated curve | Are conventions, spacing and behavior beyond the table end explicit? |
| Continued hardening is supported | Swift and the table | Does the extrapolated stress become too high? |
| An approach to saturation is observed | Voce and the table | Are Q and b separately identifiable? |
| A short interval fits both laws | Keep both as candidates | Which additional measurement or specimen can separate their predictions? |
| One law cannot represent the broader curvature | A mixed or other suitable law | Can the extra parameters be constrained? |
| Fracture must be predicted | Selected hardening plus initiation and evolution | Are fracture events, position, energy and mesh scope supported? |
There is no universal “Swift for steel, Voce for aluminum” rule. Nor do UTS and elongation alone uniquely determine a post-necking flow curve. The table is an engineering workflow proposal, not an acceptance standard.
Fit fairly, then test the prediction
- Use matched material, direction, temperature, rate, lot and thickness. Keep raw force, dimensions, strain/displacement channel and processing corrections. Do not extend a uniform-deformation conversion through necking without additional evidence. [S1, S4]
- Fit both laws to the same valid interval and weighting. Dense sampling in one part of a curve must not silently give that part greater weight. Keep repeat scatter separate from model residuals.
- Match the initial-yield convention. Swift’s
K ε0^nand Voce’s σ0 should represent the same reference. If yield is fixed using another measurement, its uncertainty has not disappeared. - Inspect residuals by region and inspect H, rather than choosing from R² alone. Derivative estimates from noisy data depend on processing and must be documented.
- Compare multiple initial guesses, bounds and near-equivalent parameter sets. At small p, Voce is approximately
σ0+(Qb)p; the data may identify the product without separating Q and b. NIST’s DP600 study illustrates why parameter uncertainty and downstream response matter. [S1] - Compare predictions over the strain range actually required, then reproduce multiple specimens using shared parameters. Material, fixture/contact and damage effects can compensate for one another if everything is freely fitted to a single force curve.
- Reserve validation specimens or loading conditions before fitting. Randomly splitting points from the same curve is not independent specimen validation. If the data do not distinguish the laws, retain the ambiguity or restrict the application range.
Model-to-model spread is not repeat-test scatter, a confidence interval or a guaranteed envelope of the real response.
An independent formula illustration
The following example uses no measured material data and no FEA runs. A declared Swift function supplies 401 uniformly spaced points over p=0–0.12. Voce is fitted to that function with the same initial flow stress. The chosen 0.12 is not a universal necking limit.
- Swift:
K=765.353452MPa, ε0=0.02, n=0.2. - Voce:
σ0=350MPa, Q≈199.896763MPa, b≈14.015271. - Fitting-window RMSE≈2.008MPa, or 1.206% of the reference stress span (maximum minus minimum).
| p | Swift MPa | Voce MPa | Voce relative to Swift |
|---|---|---|---|
| 0.05 | 449.657 | 450.707 | +0.233% |
| 0.12 | 516.521 | 512.709 | −0.738% |
| 0.30 | 609.385 | 546.913 | −10.252% |
| 0.80 | 735.571 | 549.894 | −25.243% |
These are differences between functions, not measured extrapolation errors for any alloy. The example demonstrates why a close short-range fit cannot settle a long-range prediction.

Formula CSV · Method JSON · Reproduction source ZIP
Mixed hardening functions
One convention is σy=α σSwift+(1−α)σVoce, with 0≤α≤1, α=1 for Swift and α=0 for Voce. Record the convention because weights can be defined differently elsewhere. [S2]
Extra flexibility does not automatically mean extra predictive information. Check parameter correlation, initial yield and the response of withheld specimens. Mixing two isotropic hardening functions is also distinct from combined isotropic/kinematic hardening; it does not by itself establish load-reversal or Bauschinger behavior.
Add damage as a separate model version
| Example | Hardening | Damage scope |
|---|---|---|
| Material A / Swift / v1 | Identified range plus declared extrapolation | No explicit damage model |
| Material A / Swift + Ductile / v2 | Selected Swift curve | Separately identified initiation and evolution |
| Material A / Voce + damage / v3 | Selected Voce curve | Verification of this particular combination |
Changing the underlying hardening tail changes the context in which damage parameters were identified. Recheck the combined model. Do not interpret specimen F–D work directly as material fracture energy or absorb hardening errors into initiation strain or Gf. [S3]
Record the implemented card
Keep the exact formula and coefficient units; source and processing versions; measured, inversely identified and assumed ranges; fitting settings and unresolved parameters; shared-specimen and independent-validation results; damage and mesh/solver scope; exported table resolution and endpoint behavior; and the card release actually used by each project part.
If a function is sampled into a table, do not assume the solver continues evaluating the original function beyond the last point. Display range is not validation range. A literature formula is not proof that a particular keyword is supported in an installed solver version.
Sources and scope
This independently authored selection workflow and numerical example are educational guidance, not approval of a material or a universal test method. No publisher figures or full papers are redistributed.
- [S1] NIST: DP600 Swift parameter uncertainty, author manuscript, DOI
10.1007/s11665-022-07793-2. Consulted scope: NIST summary and manuscript abstract/introduction and sensitivity discussion; not a universal result for all metals. - [S2] Altair Radioss LAW87: Swift–Voce definition. Formula reference; not an Abaqus keyword-equivalence claim.
- [S3] Abaqus: damage evolution and element removal.
- [S4] Abaqus: inelastic behavior and stress/strain measures. Current documentation is not proof of option support in Abaqus6.14-5.
Jaylab · 2026-11-15 · Evidence, assumptions and validation scope are stated in this chapter.