What happens when an elastic trial exceeds yield?
Start from virgin material: E = 200000 MPa, yield 200 MPa, H = 1000 MPa. Impose total strain 0.002 and first pretend it is all elastic.
The trial predicts 400 MPa, which is inadmissible. A plastic increment removes elastic strain and simultaneously raises the hardening limit. Solve those two changes together so the corrected stress lies on the updated surface, rather than clipping stress to the old yield value.
Connect the physical quantities
The elastic predictor ignores new plastic flow and may overshoot the yield surface. The corrector introduces plastic strain while updating the yield stress. In the uniaxial linear-hardening example, compatibility and consistency determine the correction together.
The relationship used in this example
In a small-strain model, total strain separates into elastic and plastic parts. The flow rule selects the plastic increment direction. Isotropic hardening expands the yield surface; kinematic hardening translates it. A combined model can describe both effects.
Work through the example
Trial stress is Eε = 200000×0.002 = 400 MPa.
Plastic increment is (400−200)/(200000+1000) = 0.000995025.
Corrected stress 400−200000Δλ = 200.995 MPa equals 200+1000Δλ.
Full example conditions and reference values
For a fresh uniaxial material, E = 200,000 MPa, σy0 = 200 MPa, H = 1,000 MPa and imposed total strain 0.002, the trial stress is 400 MPa. The plastic correction is Δλ = 200/201,000 = 0.000995025. Corrected stress is 200.995 MPa, equal to the updated yield stress. Elastic unloading to zero stress leaves approximately 0.000995 strain.
Compare the numbers before judging the result
| Condition | Stress (MPa) | Plastic strain | Yield level (MPa) |
|---|---|---|---|
| Elastic trial | 400 | 0 | 200 |
| After correction | 200.995 | 0.0009950249 | 200.995 |
Corrected stress equals the updated, rather than the original, yield level.
What the result means for a model
Check yield consistency, nonnegative plastic dissipation and unloading response in a single-element test before a large model. A multidimensional return mapping also needs a flow direction and tensor conventions; the scalar example does not supply those automatically.
Use a single material point under loading and unloading to verify an implementation before adding contact and complex geometry. Check yield consistency, plastic dissipation and the residual strain against the selected model, not against a different hardening convention.
Another application: Check the corrected stress against the updated surface
The 400 MPa trial stress exceeds the initial 200 MPa yield stress. After correction, plastic strain is 0.000995025 and stress is 200.995 MPa. Checking only against the original 200 MPa would wrongly classify the corrected state as inadmissible because hardening moved the surface.
Further modeling details
Associated and non-associated flow
Associated flow sets the plastic potential equal to the yield function. Other material classes may use a distinct potential. For associated J2 metal plasticity, plastic flow is volume-preserving in the small-strain formulation; that assumption does not describe foam densification.
Elastic predictor, plastic corrector
First form the trial state, test yield, then update stress and internal variables when necessary. State variables must be carried between increments. Reloading from zero history at each step would erase plastic memory.
Check the tangent meaning
For monotonic loading in this 1D example, the total stress–strain tangent in the plastic range is EH/(E+H). It differs from H, which is the slope against accumulated plastic strain. Confusing these values changes the response.
Before using a full pack
Run a one-element loading–unloading–reversal check. Compare stress, permanent strain and work. Use cyclic data for a cyclic model and test increment-size sensitivity independently of fitting accuracy.
Formula and symbol reference
Open the complete formula reference
| Symbol | Meaning | Unit / convention |
|---|---|---|
| g, f | Plastic potential; yield function | stress units in this convention |
| Δλ, α | Plastic multiplier; accumulated plastic strain in 1D example | dimensionless |
| E, H | Elastic modulus; linear isotropic hardening modulus | MPa |
| σtrial | Elastic trial stress | MPa |
When this example stops applying
The explicit return formula is only for the stated one-dimensional linear isotropic-hardening model and a plastic trial step. If the trial state is elastic, set Δλ = 0. It is not the tensor return algorithm for every material. Finite-strain plasticity needs different kinematics and stress measures.
Check your interpretation
Does a monotonic tensile fit uniquely determine behavior after load reversal?
Show the reasoning
No. Different hardening models can match the same monotonic curve but predict different reverse yielding.
Sources and calculation scope
The questions and comparison tables are independently authored teaching examples. Numbers illustrate the stated models; they are not measured cell/pack data or commercial-solver validation.
Comparison calculations (Python)
English / Korean · revised 1 November 2026