← All theory chapters
Theory / Mechanics & Materials

Plastic Flow, Hardening & Return Mapping

Understand how plastic strain evolves after the yield condition is met.

Theory · Educational notes · Related tools: Abaqus · LS-DYNA

What happens when an elastic trial exceeds yield?

Start from virgin material: E = 200000 MPa, yield 200 MPa, H = 1000 MPa. Impose total strain 0.002 and first pretend it is all elastic.

The trial predicts 400 MPa, which is inadmissible. A plastic increment removes elastic strain and simultaneously raises the hardening limit. Solve those two changes together so the corrected stress lies on the updated surface, rather than clipping stress to the old yield value.

Connect the physical quantities

The elastic predictor ignores new plastic flow and may overshoot the yield surface. The corrector introduces plastic strain while updating the yield stress. In the uniaxial linear-hardening example, compatibility and consistency determine the correction together.

The relationship used in this example

Δλ=∣σtrial∣−(σy0+Hαn)E+H\Delta\lambda=\frac{|\sigma_{\mathrm{trial}}|-(\sigma_{y0}+H\alpha_n)}{E+H}

In a small-strain model, total strain separates into elastic and plastic parts. The flow rule selects the plastic increment direction. Isotropic hardening expands the yield surface; kinematic hardening translates it. A combined model can describe both effects.

Work through the example

Step 1

Trial stress is Eε = 200000×0.002 = 400 MPa.

Step 2

Plastic increment is (400−200)/(200000+1000) = 0.000995025.

Step 3

Corrected stress 400−200000Δλ = 200.995 MPa equals 200+1000Δλ.

Full example conditions and reference values

For a fresh uniaxial material, E = 200,000 MPa, σy0 = 200 MPa, H = 1,000 MPa and imposed total strain 0.002, the trial stress is 400 MPa. The plastic correction is Δλ = 200/201,000 = 0.000995025. Corrected stress is 200.995 MPa, equal to the updated yield stress. Elastic unloading to zero stress leaves approximately 0.000995 strain.

Compare the numbers before judging the result

Compare the calculated values
ConditionStress (MPa)Plastic strainYield level (MPa)
Elastic trial4000200
After correction200.9950.0009950249200.995

Corrected stress equals the updated, rather than the original, yield level.

What the result means for a model

Check yield consistency, nonnegative plastic dissipation and unloading response in a single-element test before a large model. A multidimensional return mapping also needs a flow direction and tensor conventions; the scalar example does not supply those automatically.

Use a single material point under loading and unloading to verify an implementation before adding contact and complex geometry. Check yield consistency, plastic dissipation and the residual strain against the selected model, not against a different hardening convention.

Another application: Check the corrected stress against the updated surface

The 400 MPa trial stress exceeds the initial 200 MPa yield stress. After correction, plastic strain is 0.000995025 and stress is 200.995 MPa. Checking only against the original 200 MPa would wrongly classify the corrected state as inadmissible because hardening moved the surface.

Further modeling details

Associated and non-associated flow

Associated flow sets the plastic potential equal to the yield function. Other material classes may use a distinct potential. For associated J2 metal plasticity, plastic flow is volume-preserving in the small-strain formulation; that assumption does not describe foam densification.

Elastic predictor, plastic corrector

First form the trial state, test yield, then update stress and internal variables when necessary. State variables must be carried between increments. Reloading from zero history at each step would erase plastic memory.

Check the tangent meaning

For monotonic loading in this 1D example, the total stress–strain tangent in the plastic range is EH/(E+H). It differs from H, which is the slope against accumulated plastic strain. Confusing these values changes the response.

Before using a full pack

Run a one-element loading–unloading–reversal check. Compare stress, permanent strain and work. Use cyclic data for a cyclic model and test increment-size sensitivity independently of fitting accuracy.

Formula and symbol reference

Open the complete formula reference
dεp=dλ∂g∂σ\mathrm d\boldsymbol\varepsilon^p=\mathrm d\lambda\frac{\partial g}{\partial\boldsymbol\sigma}
dλ≥0,f≤0,dλf=0\mathrm d\lambda\geq0,\quad f\leq0,\quad \mathrm d\lambda f=0
σtrial=E(εn+1−εnp)\sigma_{\mathrm{trial}}=E(\varepsilon_{n+1}-\varepsilon_n^p)
Δλ=∣σtrial∣−(σy0+Hαn)E+H\Delta\lambda=\frac{|\sigma_{\mathrm{trial}}|-(\sigma_{y0}+H\alpha_n)}{E+H}
σn+1=σtrial−EΔλ sign⁡(σtrial)\sigma_{n+1}=\sigma_{\mathrm{trial}}-E\Delta\lambda\,\operatorname{sign}(\sigma_{\mathrm{trial}})
SymbolMeaningUnit / convention
g, fPlastic potential; yield functionstress units in this convention
Δλ, αPlastic multiplier; accumulated plastic strain in 1D exampledimensionless
E, HElastic modulus; linear isotropic hardening modulusMPa
σtrialElastic trial stressMPa

When this example stops applying

The explicit return formula is only for the stated one-dimensional linear isotropic-hardening model and a plastic trial step. If the trial state is elastic, set Δλ = 0. It is not the tensor return algorithm for every material. Finite-strain plasticity needs different kinematics and stress measures.

Check your interpretation

Does a monotonic tensile fit uniquely determine behavior after load reversal?

Show the reasoning

No. Different hardening models can match the same monotonic curve but predict different reverse yielding.

Sources and calculation scope

The questions and comparison tables are independently authored teaching examples. Numbers illustrate the stated models; they are not measured cell/pack data or commercial-solver validation.

Comparison calculations (Python)