Why does temperature approach a limit gradually?
A 0.1 kg lumped body has cp = 1000 J/(kg·K), heat loss coefficient hA = 0.5 W/K and constant generation 2 W. It starts at ambient temperature.
Initially there is no temperature difference and little heat loss. Stored heat raises temperature; the growing temperature difference then increases heat loss. At the final rise, loss equals generation. Heat capacity determines how quickly that balance is approached.
Connect the physical quantities
The lumped heat balance treats the body as having one temperature. Heat capacity controls how quickly it warms; thermal conductance controls the final rise under constant heating. Improving cooling and increasing thermal mass therefore change different parts of the transient response.
The relationship used in this example
A lumped thermal model treats the cell as one temperature. Heat generation raises stored thermal energy, while heat transfer to the surroundings removes it. This approximation is useful when internal temperature gradients are small enough for the intended output. Temperature can also change electrochemical parameters, so a coupled calculation must state which quantities pass between the thermal and electrochemical models.
Work through the example
Heat capacity is mcp = 0.1×1000 = 100 J/K.
Steady rise is 2/0.5 = 4 K and time constant is 100/0.5 = 200 s.
At 200 s the rise is 4(1−e⁻¹) = 2.528 K, about 63.2% of the final rise.
Full example conditions and reference values
For m = 0.1 kg, cp = 1,000 J/(kg·K), hA = 0.5 W/K and constant Q̇gen = 2 W, the steady temperature rise is 4 K and the time constant is 200 s. Starting at ambient, ΔT = 4(1 − exp(−t/200)) K.
Compare the numbers before judging the result
| hA (W/K) | Steady rise (K) | Time constant (s) | Rise at 200 s (K) |
|---|---|---|---|
| 0.5 | 4 | 200 | 2.528482 |
| 1 | 2 | 100 | 1.729329 |
Increasing cooling changes both the final temperature and the rate of approach.
What the result means for a model
A cooling plate can make temperatures nonuniform even when average temperature looks acceptable. Use a spatial thermal model when gradients control thermal stress or material properties. Mechanical contact pressure may also affect thermal resistance, requiring more than a one-way temperature transfer.
For thermal stress, map temperature relative to the assembly reference rather than applying the final absolute temperature as a temperature change. A uniform-temperature model can estimate overall expansion but cannot locate a hot-spot stress concentration.
Another application: Evaluate the transient, not just the final temperature
With a 4 K steady rise and 200 s time constant, the rise is 2.528 K at 200 s and 3.801 K at 600 s. Doubling hA halves both the steady rise and the time constant when mass, heat capacity and heat generation remain fixed.
Formula and symbol reference
Open the complete formula reference
| Symbol | Meaning | Unit / convention |
|---|---|---|
| m, cp | Mass and specific heat | kg; J/(kg·K) |
| Q̇gen | Total heat-generation rate | W |
| h, A | Heat-transfer coefficient and exposed area | W/(m²·K); m² |
| RΩ | Ohmic resistance | Ω |
| T, T∞ | Cell and ambient temperature | K |
When this example stops applying
I²R includes only an ohmic contribution. Reaction and reversible entropic heat can matter; entropic heat may change sign. Thermal runaway needs reaction and abuse models beyond this balance. A lumped temperature does not resolve hotspots or propagation between cells.
Check your interpretation
If hA doubles with the same heat generation and thermal mass, what changes?
Show the reasoning
Both the steady temperature rise and the time constant halve.
Sources and calculation scope
The questions and comparison tables are independently authored teaching examples. Numbers illustrate the stated models; they are not measured cell/pack data or commercial-solver validation.
Comparison calculations (Python)
English / Korean · revised 1 November 2026