Why can a smaller particle respond faster?
Take particle radius 5 μm and diffusivity 10⁻¹⁴ m²/s. Estimate the diffusion time scale, then change radius or diffusivity separately.
Diffusion must redistribute concentration over a distance. The scale grows with distance squared, so halving radius has a stronger effect than merely halving a travel time. Reaction kinetics adds a separate resistance at the interface; this diffusion estimate alone cannot predict charging cutoff.
Connect the physical quantities
Diffusion redistributes lithium inside a particle, while interface kinetics governs transfer across its boundary. Their characteristic limitations are different. A particle can have an average concentration compatible with a chosen SOC while its surface concentration is much higher or lower.
The relationship used in this example
For a spherical active-material particle, radial diffusion changes the surface concentration available to the reaction. Butler–Volmer kinetics relates reaction current density to overpotential. Particle diffusion and reaction kinetics are different limitations; fitting a voltage curve does not automatically identify both uniquely.
Work through the example
Convert 5 μm to 5×10⁻⁶ m and square it: 25×10⁻¹² m².
Divide by 10⁻¹⁴ m²/s to obtain a scale of 2500 s.
Halving radius quarters R², giving 625 s without changing D.
Full example conditions and reference values
With Rₚ = 5 μm and D = 10⁻¹⁴ m²/s, the order-of-magnitude diffusion time is 2,500 s. Halving the radius reduces this estimate to 625 s. This scale is not an exact charge time or a cutoff prediction.
Compare the numbers before judging the result
| Radius (μm) | D (m²/s) | R²/D (s) |
|---|---|---|
| 5 | 1e-14 | 2500 |
| 2.5 | 1e-14 | 625 |
| 5 | 2e-14 | 1250 |
Compare length squared against a linear change in diffusivity; these are scales, not exact completion times.
What the result means for a model
This estimate indicates whether internal gradients may matter; it does not provide the exact time to a voltage cutoff. A uniform swelling strain can describe average size change while missing stresses driven by concentration gradients. Match the spatial scale of the chemistry model to the structural question.
A fitted voltage curve can hide compensation between particle size, diffusion and reaction parameters. For stress coupling, inspect the surface-to-center concentration difference as well as the average; equal average concentration need not imply equal internal gradients.
Another application: Compare particle size and diffusivity separately
For a 5 μm particle and D = 10⁻¹⁴ m²/s, R²/D is 2,500 s. Reducing radius to 2.5 μm gives 625 s; keeping radius and doubling D instead gives 1,250 s. These are characteristic scales, not a predicted completion time.
Formula and symbol reference
Open the complete formula reference
| Symbol | Meaning | Unit / convention |
|---|---|---|
| c, D | Solid concentration and diffusivity | mol/m³; m²/s |
| r, Rₚ | Radial coordinate and particle radius | m |
| j, j₀ | Interfacial and exchange current densities | A/m² |
| η, φs, φe | Overpotential; solid/electrolyte potentials | V |
| αₐ, αc | Charge-transfer coefficients | dimensionless |
| F, R, T | Faraday constant, gas constant, temperature | C/mol; J/(mol·K); K |
When this example stops applying
The displayed kinetics uses a one-electron convention. Particle diffusion needs a center-symmetry condition and a surface-flux condition tied to reaction current. SPM simplifies each electrode to a representative particle; electrolyte transport requires additional treatment such as SPMe or DFN.
Check your interpretation
Can fast particle diffusion eliminate all terminal voltage losses?
Show the reasoning
No. Reaction kinetics, electrolyte transport, electronic resistance and contacts can still contribute.
Sources and calculation scope
The questions and comparison tables are independently authored teaching examples. Numbers illustrate the stated models; they are not measured cell/pack data or commercial-solver validation.
Comparison calculations (Python)
English / Korean · revised 1 November 2026