← All theory chapters
Theory / Dynamics & Crash

Preloaded Modes & Damping Identification

Connect an assembled equilibrium state to small-vibration modes and estimate damping from an isolated free-decay response.

Theory · Educational notes

Which stiffness belongs in a vibration model after assembly?

For a 10 kg mass, compare tangent stiffness 100000 and 144000 N/m. Separately use decay peaks 1.0 and 0.5 mm that are three cycles apart over 0.15 s.

Small vibrations sample the tangent around the assembled equilibrium, not an average slope from zero load. Damping identification uses amplitude decay per cycle. The stiffness comparison and decay record are independent examples; combining their numbers as one measured model would be incorrect.

Connect the physical quantities

The relationship used in this example

fn=12πktmf_n=\frac{1}{2\pi}\sqrt{\frac{k_t}{m}}

A modal calculation describes small motion around a particular equilibrium. Bolt preload, pad compression and contact status help define that state. Natural frequency, mode shape and damping answer different questions: a correct frequency does not prove a correct resonance amplitude or decay rate.

Work through the example

Step 1

A: f₂/f₁ = √(144000/100000) = 1.2; convert N/mm to N/m before using kg.

Step 2

B: δlog = ln(1/0.5)/3 = 0.231049, so ζ = 0.036748.

Step 3

B: Td = 0.15/3 = 0.05 s; fd = 20 Hz, fn = 20.0135 Hz and c = 92.42 N·s/m for 10 kg.

Full example conditions and reference values

Two independent synthetic demonstrations: A) m = 10 kg with kt changing from 100000 to 144000 N/m gives fn = 15.9155 to 19.0986 Hz, a 20% increase. B) an isolated viscously damped SDOF trace has same-sign peaks 1.0 and 0.5 mm three cycles apart over 0.15 s. Then δlog = 0.231049, ζ = 0.036748 (3.6748%), fd = 20 Hz and fn = 20.0135 Hz. If the mass in B is 10 kg, c = 92.42 N·s/m. Case B is not the response of Case A.

Preloaded Modes & Damping Identification — synthetic analytical example
Original Jaylab analytical illustration. Synthetic inputs; not a measured battery or pack response.

Compare the numbers before judging the result

Compare the calculated values
kt (N/m)fn at 10 kg (Hz)
10000015.91549
14400019.09859

A 44% tangent stiffness increase produces a 20% frequency increase. Damping is identified separately from the decay record.

What the result means for a model

Use a segment dominated by one mode and inspect whether the decay is approximately exponential. Beating, friction and changing contact can invalidate an SDOF viscous fit even if two selected peaks yield a plausible number.

Another application: Damping identification needs comparable peaks

Peaks of 1.0 and 0.5 mm three cycles apart give logarithmic decrement ln(2)/3 = 0.23105. Treating them as adjacent cycles would triple the decrement and greatly overestimate damping. The 0.15 s interval also gives a damped period of 0.05 s, not 0.15 s.

Further modeling details

Establish the assembled base state

Solve and inspect static equilibrium before extracting modes. Record tightened joints, pad compression, support constraints and contact pressure. Carry the intended preloading history into the perturbation step rather than adding a label to an otherwise unloaded model. Check force balance and rigid-body motion first.

Use tangent stiffness, not an arbitrary secant

For a nonlinear pad law F(δ), small vibration uses a local slope dF/dδ near the operating compression. F/δ is a secant and need not equal that slope. Prestress can also contribute geometric stiffness. These mechanisms can increase or decrease frequencies; preload does not universally stiffen every mode.

Know where linear perturbation stops

A linearized model cannot freely switch between open contact, closed contact and frictional slip during a cycle. If the response amplitude crosses a gap or changes the sticking state, assess nonlinear transient behavior. Inspect the chosen solver’s base-state contact treatment. A linear mode shape alone does not establish the amplitude range over which contact is maintained.

Extract decay from one mode

Use free vibration after the forcing ends, remove a justified offset and identify same-sign peaks. Count complete cycles between peaks; adjacent positive and negative extrema are only half a cycle apart. Beating, multiple modes, drift and sensor noise can bias the logarithmic decrement. Fit several peaks and compare windows rather than selecting the cleanest two.

Keep damping separate from frequency fitting

Case A changes stiffness while Case B estimates decay. Matching frequency can constrain a stiffness-to-mass ratio but does not identify damping. A damping coefficient that suppresses a bad resonance curve may hide a wrong support or mode shape. Compare mode pairing, frequency, decay and forced-response amplitude as separate observables.

Use an assembly comparison matrix

Compare untightened, assembled and representative swollen states with the same mass and sensor mapping where appropriate. Change one assumption at a time. When viscoelastic pads contribute, record temperature, frequency and preload; a long-hold static modulus is not automatically the dynamic stiffness. Reserve a second amplitude or preload state as a prediction check.

Formula and symbol reference

Open the complete formula reference
[Kt(u0)−ωn2M]ϕ=0[\mathbf K_t(\mathbf u_0)-\omega_n^2\mathbf M]\boldsymbol\phi=\mathbf0
fn=12πktmf_n=\frac{1}{2\pi}\sqrt{\frac{k_t}{m}}
δlog⁡=1nln⁡∣xi∣∣xi+n∣\delta_{\log}=\frac{1}{n}\ln\frac{|x_i|}{|x_{i+n}|}
ζ=δlog⁡4π2+δlog⁡2\zeta=\frac{\delta_{\log}}{\sqrt{4\pi^2+\delta_{\log}^2}}
fd=1Td,fn=fd1−ζ2f_d=\frac{1}{T_d},\qquad f_n=\frac{f_d}{\sqrt{1-\zeta^2}}
c=2ζm(2πfn)c=2\zeta m(2\pi f_n)
SymbolMeaningUnit / convention
Kt, u₀, MTangent stiffness, assembled equilibrium and mass matrixconsistent force–length–time units
kt, mIllustrative SDOF tangent stiffness and massN/m; kg
xi, xi+n, nSame-sign peak amplitudes and number of complete intervening cyclesmm; mm; integer
ζ, fn, fd, cDamping ratio, natural/damped frequency, viscous dampingdimensionless; Hz; Hz; N·s/m

When this example stops applying

Small oscillations around a stable equilibrium; the decay example assumes an isolated underdamped linear mode with viscous damping. It is not an experimental modal fit or a nonlinear contact solve. Frequency-dependent or frictional damping requires additional identification. Prestress effects depend on formulation and base-state setup.

Check your interpretation

Does a 20% increase in natural frequency imply a 20% increase in stiffness at unchanged mass?

Show the reasoning

No. In the SDOF example stiffness is proportional to frequency squared: 1.2² = 1.44, or a 44% stiffness increase.

Sources and calculation scope

The questions and comparison tables are independently authored teaching examples. Numbers illustrate the stated models; they are not measured cell/pack data or commercial-solver validation.

Comparison calculations (Python)

English / Korean · revised 1 November 2026