Why can a visible mode respond weakly to base motion?
Use M = diag(2,2) kg, uniform input r = [1,1], and demonstration shapes [1,1] and [1,−1]. Compare participation before and after rescaling a shape.
Participation projects the input onto a mode using the mass matrix. Equal base forces reinforce in the in-phase shape but cancel in the opposite-phase shape. Effective mass removes the arbitrary amplitude used to draw a mode; visual size is not participation.
Connect the physical quantities
A mode can exist without being strongly excited by a particular input. Participation depends on the spatial loading direction and mass distribution. Eigenvector amplitude is arbitrary; a correctly defined effective mass remains invariant when the vector is rescaled.
The relationship used in this example
A mode’s frequency does not determine its excitation strength. Modal participation depends on the mass distribution, mode shape and excitation direction. Effective modal mass is invariant to rescaling a mode, whereas the participation factor generally is not.
Work through the example
For φ = [1,1], φᵀMφ = 4 kg and φᵀMr = 4 kg.
Participation is 1 and effective mass is 4²/4 = 4 kg.
For φ = [1,−1], the forcing numerator cancels to zero, so effective mass for this input is zero.
Full example conditions and reference values
Let M = diag(2, 2) kg, φ₁ = [1, 1], φ₂ = [1, −1] and uniform base influence r = [1, 1]. Both generalized masses are 4 kg, but Γ₁ = 1 and Γ₂ = 0. Their effective masses are 4 and 0 kg. Rescaling φ₁ to [2, 2] gives generalized mass 16 kg and Γ₁ = 0.5, leaving effective mass 4 kg unchanged. These are algebraic demonstration vectors, not measured pack modes.
Compare the numbers before judging the result
| Condition | Generalized mass (kg) | Γ | Effective mass (kg) |
|---|---|---|---|
| [1,1] | 4 | 1 | 4 |
| [2,2] | 16 | 0.5 | 4 |
| [1,−1] | 4 | 0 | 0 |
Input direction is [1,1]. Rescaling a mode does not change its effective mass for that input.
What the result means for a model
A low global effective mass does not imply negligible local stress under every load. A local force or different excitation direction can couple to that mode. Choose retained modes using the actual input and output of interest, then check truncation sensitivity.
Compare effective mass in a specified direction, not the displayed amplitude or participation factor alone. Low effective mass for uniform base motion does not exclude a response to a localized force at a mode antinode.
Another application: Rescaling the plotted mode should change no prediction
For M = diag(2,2) kg and r = [1,1], the vector [1,1] has generalized mass 4 kg and Γ = 1. Scaling it to [2,2] gives 16 kg and Γ = 0.5. In both cases Γ² times generalized mass is 4 kg.
Further modeling details
Start with the excitation
Specify whether the model is driven by base motion or applied forces. Uniform vertical base motion, a local module force and an acoustic load have different spatial distributions. A participation table must be read in that context.
Mode-count convergence
Increase the retained frequency range and compare the actual output of interest: mount force, module acceleration or a selected stress measure. Choose a truncation criterion from those comparisons rather than treating one universal mass fraction as sufficient.
Pack and module interpretation
A global tray mode may dominate total effective mass while a local cover mode contributes little. The local mode may still matter at a sensor, a connector or under nearby forcing. Review spatial shapes alongside the mass table.
Keep normalization explicit
Record mode normalization and coordinate conventions when exchanging results. Sign changes and scalar rescaling do not represent different physical shapes. Preserve the raw eigenvectors and mass definitions when checking participation calculations.
Formula and symbol reference
Open the complete formula reference
| Symbol | Meaning | Unit / convention |
|---|---|---|
| M | Mass matrix for the modeled free degrees of freedom | kg for translational DOFs |
| φj | Real mode vector | normalization-dependent |
| r | Influence vector for a specified base-translation direction | dimensionless here |
| mj, meff,j | Generalized and effective modal mass | kg for the illustrated normalization |
| Γj, ρJ | Participation factor; cumulative effective-mass ratio | normalization-dependent; dimensionless |
When this example stops applying
The displayed expressions assume real linear modes and a consistent mass matrix. Rotational influence vectors and units require care. Completeness refers to the represented direction and free DOFs. High cumulative effective mass does not guarantee accurate local stress, contact response or every excitation pattern.
Check your interpretation
Can a mode with zero effective mass for uniform vertical base excitation still matter under another load?
Show the reasoning
Yes. A local force or a different excitation direction can couple to it.
Sources and calculation scope
- SIMULIA · Participation factors and effective modal mass
- MIT OCW · Multi-degree-of-freedom vibration
The questions and comparison tables are independently authored teaching examples. Numbers illustrate the stated models; they are not measured cell/pack data or commercial-solver validation.
Comparison calculations (Python)
English / Korean · revised 1 November 2026