Can one curve distinguish material softness from fixture softness?
Use area 100 mm² and two lengths 10 and 20 mm. Measured compliances are 0.0015 and 0.0025 mm/N under the same fixture condition.
One measured compliance combines specimen and fixture contributions. Subtracting two tests with unchanged fixture compliance cancels that nuisance term. The remaining length-dependent change identifies EA, after which the fixture term can be recovered.
Connect the physical quantities
The relationship used in this example
Curve fitting finds parameters that reproduce selected measurements. Identification asks whether those measurements distinguish the parameters at all. A small residual can coexist with many parameter combinations, especially when fixture flexibility and specimen compliance act in series.
Work through the example
Subtract measured compliances: 0.0025−0.0015 = 0.0010 mm/N.
Compute E = (20−10)/(100×0.0010) = 100 MPa.
Recover Cf = 0.0015−10/(100×100) = 0.0005 mm/N and predict both tests again.
Full example conditions and reference values
For a synthetic uniform bar with L1 = 10 mm and A = 100 mm², measured compliance Cm1 = 0.0015 mm/N is compatible with both (E = 100 MPa, Cf = 0.0005 mm/N) and (E = 200 MPa, Cf = 0.0010 mm/N). A second specimen of the same material and area with L2 = 20 mm gives Cm2 = 0.0025 mm/N. Under unchanged fixture compliance, the two lengths identify E = 100 MPa and Cf = 0.0005 mm/N. The alternative predicts 0.0020 mm/N for the second test and no longer fits.
Compare the numbers before judging the result
| Condition | E (MPa) | Cf (mm/N) | Cm at L=10 (mm/N) | Cm at L=20 (mm/N) |
|---|---|---|---|---|
| Candidate A | 100 | 0.0005 | 0.0015 | 0.0025 |
| Candidate B | 200 | 0.001 | 0.0015 | 0.002 |
Both match the first test; only A matches the second compliance 0.0025 mm/N under the common-fixture assumption.
What the result means for a model
Changing specimen length must not also change gripping slip or contact conditions. Otherwise the second test adds an unknown instead of separating the first two. Inspect parameter sensitivity before running a large optimization.
Another application: A second specimen length separates two effects
The compliance difference 0.0025−0.0015 = 0.0010 mm/N comes from the extra 10 mm specimen length when fixture compliance is unchanged. Thus EA = 10/0.0010 = 10,000 N, E = 100 MPa, and the first test leaves fixture compliance 0.0005 mm/N.
Further modeling details
Define observations before parameters
List what is measured: force, local displacement, strain field, lateral contraction or modal response. Then list unknowns. A nominal force–crosshead curve can mix material stiffness, geometry, friction and machine compliance. Optimizing them simultaneously does not create information that is absent from the observations.
Use a scale-aware objective
Normalize residuals with justified measurement uncertainties or explicitly stated engineering scales. Otherwise a force channel expressed in newtons can dominate a displacement channel expressed in millimetres solely because of its numeric magnitude. Do not treat arbitrary weights as statistical confidence.
Recognize indistinguishable effects
In the first test, only the sum L/(EA)+Cf is observed. Many E and Cf pairs preserve it. More points on the same perfectly linear force curve improve slope precision but still do not separate those two contributions. A different length changes material compliance without intentionally changing fixture compliance.
Check the design assumptions
The two-length derivation assumes identical material and area, uniform uniaxial strain and unchanged fixture compliance. Layered pouch cells do not generally behave like bars whose gauge length can be freely doubled. For cells, use independently measured fixture compliance, local thickness measurements and complementary loading modes instead of blindly scaling geometry.
Reserve a validation condition
Fit a bounded parameter set, record alternative near-optimal solutions and inspect sensitivity. Use a withheld load path, rate or temperature to test predictive behavior. If every parameter is changed for each new test, the process is repeated fitting rather than validation of one transferable model.
Formula and symbol reference
Open the complete formula reference
| Symbol | Meaning | Unit / convention |
|---|---|---|
| J, θ | Weighted residual objective and model parameters | dimensionless objective when si has output units |
| L, A, E | Gauge length, cross-sectional area and modulus | mm; mm²; MPa |
| Cm, Cf | Measured and fixture compliance | mm/N |
| si, Sij | Measurement scale and local parameter sensitivity | output units; output/parameter units |
When this example stops applying
The identifiability demonstration is exact only for the stated linear model. Real inverse problems can be nonlinear, noisy and globally nonunique. A local sensitivity matrix is informative but does not prove global uniqueness.
Check your interpretation
Will collecting more points on the same linear force–displacement path separate E and fixture compliance?
Show the reasoning
Not by itself. It can reduce uncertainty in the combined slope, but an independent measurement or a changed test configuration is needed to separate the contributions in this example.
Sources and calculation scope
- NIST Engineering Statistics Handbook · Nonlinear least squares
- Doherty & Hunt · Parameter identifiability and error reduction
- Instron · Universal Testing Machine Compliance (measurement background)
The questions and comparison tables are independently authored teaching examples. Numbers illustrate the stated models; they are not measured cell/pack data or commercial-solver validation.
Comparison calculations (Python)
English / Korean · revised 1 November 2026