← All theory chapters
Theory / Contact & Connections

Nonlinear Pad Compression & Stack Load Sharing

Solve swelling compatibility from an assembled reference using a nonlinear pad compression curve.

Theory · Educational notes

Why does the initial pad stiffness underpredict added force?

Use two 3 mm pads of area 10000 mm² in series, p = 0.2ε + 4ε³ MPa, initial force 500 N and other compliance 0.00004 mm/N. Add 0.8 mm free swelling.

Both pads carry the same force, but their tangent stiffness rises as compression increases. Solve force compatibility from the assembled strains, not from zero compression. An initial tangent is a local slope; extrapolating it over the full motion ignores the stiffening curve.

Connect the physical quantities

For nonlinear pads, force equilibrium and displacement compatibility must be solved together. The pad strain is obtained from its inverse pressure law at the common force. An assembled preload chooses a point on that law, so subsequent swelling uses incremental compression from that point.

The relationship used in this example

Δsw=(F−F0)Cother+Δp\Delta_{\mathrm{sw}}=(F-F_0)C_{\mathrm{other}}+\Delta_p

A pad does not necessarily have one constant modulus over its working range. Its force can increase slowly over one compression interval and rapidly over another. A series stack must satisfy both common axial force and a displacement budget: free swelling is accommodated by additional pad compression, cell compression and housing opening. The reference state decides whether those are total or incremental quantities.

Work through the example

Step 1

Initial nominal pressure is 500/10000 = 0.05 MPa; invert the law to obtain strain 0.163148.

Step 2

The final common force 1549.354 N gives strain 0.289486.

Step 3

Two pads add 2×3×(0.289486−0.163148) ≈ 0.758026 mm; other compliance adds 0.041974 mm.

Full example conditions and reference values

Use two full-face pads in series, each with free thickness 3 mm and area 10,000 mm². Define the synthetic nominal pressure law p = 0.2ε + 4ε³ MPa for 0 ≤ ε ≤ 0.6, Cother = 0.00004 mm/N, and assembled force F0 = 500 N. The initial strain is 0.163148. For 0.8 mm additional free swelling, scalar compatibility gives F = 1549.354 N and ε = 0.289486. Additional pad compression is 0.758026 mm and the other elastic contribution is 0.041974 mm, summing to 0.8 mm. The force increase is 1049.354 N. Linearizing only at the initial state predicts 669.367 N increase, which is smaller because the example curve stiffens.

Original Jaylab nonlinear scalar example, referenced to a precompressed 500 N assembly. The polynomial is synthetic and not a commercial pad property. The chart compares full-curve equilibrium with the initial tangent approximation.
Original Jaylab nonlinear scalar example, referenced to a precompressed 500 N assembly. The polynomial is synthetic and not a commercial pad property. The chart compares full-curve equilibrium with the initial tangent approximation.

Compare the numbers before judging the result

Compare the calculated values
Added growth (mm)Total force (N)Force increase (N)Pad increase (mm)
050000
0.4921.9024421.90240.3831239
0.81549.3541049.3540.7580258

Every row uses the assembled 500 N reference. Pad compression plus (F−500)×0.00004 closes each growth budget.

What the result means for a model

Tangent stiffness predicts only a local increment. A large excursion into densification needs the full measured curve. Compression data do not automatically define unloading, creep or stress relaxation; those require additional history-dependent information.

Bracket the scalar equilibrium within the measured pad-strain range before solving. A mathematical root outside the calibrated compression range is extrapolation. For unloading or a long hold, the loading curve alone may omit hysteresis and relaxation.

Another application: Total force and added force have different references

The nonlinear example starts at F0 = 500 N and ends at 1549.354 N. The added force is 1049.354 N, not 1549.354 N. The 0.8 mm budget uses changes from the assembled pad strain, not compression from the pad’s free thickness.

Further modeling details

1 · Start from a measured curve, not a label

A physical pad model needs compression data with thickness, area, loading direction, temperature, rate and conditioning recorded. Distinguish nominal stress based on reference area from true stress. A manufacturer’s compression-force-deflection curve is not automatically a universal uniaxial material law: lateral constraint and friction affect the apparent response. The polynomial here is invented solely to make compatibility transparent; it is not fitted to a commercial pad.

2 · Keep serial and parallel paths distinct

Full-face layers in an ideal one-dimensional series path carry the same axial resultant, even if their areas differ. Their pressures then differ as F/Aj, and their compressions add. Side-by-side supports under a rigid parallel plate share displacement and their forces add; that is a different topology. Adding another serial pad increases compliance in this model, while increasing parallel contact area generally does not have that effect.

3 · Subtract the assembled state

For an already precompressed stack, subtract each pad’s initial compression at F0 from its compression at F. Multiply the force increase, not total force, by the linear compliance. Adding F0 after solving a zero-preload problem is generally wrong for nonlinear pads because the slope depends on the initial compression. If there is a true open gap instead, free expansion must consume that gap before the common compressive load path engages.

4 · Solve a bounded scalar equilibrium

For a monotone pad curve, invert pressure to strain and form a residual: predicted total additional accommodation minus prescribed free swelling. Bracket a force interval that stays inside every curve’s valid domain, then use bisection or another safeguarded method. A small residual establishes compatibility of this reduced model, not material validity. If the target cannot be bracketed within measured data, report the range limit instead of silently extrapolating.

5 · Use tangent stiffness at the right state

A secant modulus describes a ratio across a finite range; tangent stiffness describes a small change at the current state. In the synthetic example the tangent rises with compression, so a fixed initial tangent understates the force increase over 0.8 mm. Use the full curve for the finite loading step. If a small-amplitude vibration model is subsequently linearized about the final assembly, use an appropriate local stiffness and damping representation at that operating state.

6 · Know what the scalar model cannot resolve

Moving an identical serial pad to another position has no effect in this idealization. Real endplate bending, partial footprints, friction and nonuniform cell swelling can make position important. Relaxation changes force during a displacement hold, creep changes deformation under load, and unloading can follow a different path. These effects require time/history-dependent data and a model that carries that state, not this single monotone curve.

Formula and symbol reference

Open the complete formula reference
F=Ajpj(εj),δj=tjεjF=A_jp_j(\varepsilon_j),\quad\delta_j=t_j\varepsilon_j
p(ε)=aε+bε3p(\varepsilon)=a\varepsilon+b\varepsilon^3
kt,j=Ajtjdpjdεjk_{t,j}=\frac{A_j}{t_j}\frac{\mathrm dp_j}{\mathrm d\varepsilon_j}
Δsw=(F−F0)Cother+Δp\Delta_{\mathrm{sw}}=(F-F_0)C_{\mathrm{other}}+\Delta_p
Δp=∑jtjΔεj\Delta_p=\sum_jt_j\Delta\varepsilon_j
Δεj=εj(F/Aj)−εj(F0/Aj)\Delta\varepsilon_j=\varepsilon_j(F/A_j)-\varepsilon_j(F_0/A_j)
dFdΔsw=(Cother+∑j1kt,j)−1\frac{\mathrm dF}{\mathrm d\Delta_{\mathrm{sw}}}=\left(C_{\mathrm{other}}+\sum_j\frac1{k_{t,j}}\right)^{-1}
SymbolMeaningUnit / convention
F, F0Common total axial force and assembled-reference forceN
Aj, tjReference pad area and free thicknessmm²; mm
εj(p)Inverse compression curve; compressive engineering strain positivedimensionless
p, a, bNominal compressive stress and illustrative polynomial coefficientsMPa
CotherCombined linear cell-compression and housing-opening compliancemm/N
Δsw, kt,jAdditional free swelling; current tangent pad stiffnessmm; N/mm
Δp, ΔεjTotal additional pad compression; strain change from assembled referencemm; dimensionless

When this example stops applying

Uniform axial series force, fixed reference areas and full contact; positive additional swelling from a specified assembled preload. Cells and housing are represented only by a linear compliance. The example pad law is restricted to engineering strain 0–0.6 and is not a validated battery material model. No unloading, relaxation, friction or spatial pressure distribution is computed. This is a theory note, not an update to the deployed Swelling solver.

Check your interpretation

Do two serial pads necessarily each take half of the total compression?

Show the reasoning

Only if their force–compression laws and dimensions are identical in the same state. Series equilibrium makes force equal, not displacement. Different thicknesses, areas or curves lead to different compressions at that common force.

Sources and calculation scope

The questions and comparison tables are independently authored teaching examples. Numbers illustrate the stated models; they are not measured cell/pack data or commercial-solver validation.

Comparison calculations (Python)

English / Korean · revised 1 November 2026