Can the same resultant hide a different pressure field?
Divide a 10000 mm² face into four equal patches at pressures 0.05, 0.10, 0.15 and 0.10 MPa. Compare their resultant with uniform 0.10 MPa.
Pressure times patch area gives local force; sum those forces to obtain the resultant. Averaging alone discards spatial variation. A finite sensor averages over its footprint, so compare the same footprint rather than a sensor reading against the FE maximum.
Connect the physical quantities
The relationship used in this example
A force sensor measures a resultant; a pressure map describes how that force is distributed. The same total force can correspond to uniform loading, edge loading or partial contact. A stack model that predicts average force therefore cannot establish local cell pressure by itself.
Work through the example
Each patch area is 10000/4 = 2500 mm².
Multiply pressures by area: [125,250,375,250] N; their sum is 1000 N.
Mean pressure is 1000/10000 = 0.1 MPa. RMS deviation is √((0.05²+0+0.05²+0)/4) = 0.035355 MPa.
Full example conditions and reference values
Divide a synthetic 10000 mm² face into four equal nonoverlapping patches with pressures [0.05,0.10,0.15,0.10] MPa. Their resultant is 1000 N, area mean is 0.10 MPa and area-weighted standard deviation is 0.035355 MPa, giving CVA = 0.353553. A uniform 0.10 MPa field has the same resultant but CVA = 0. A sensor spanning the first two equal patches reads an ideal footprint average of 0.075 MPa, not the 0.15 MPa maximum.
Compare the numbers before judging the result
| Condition | Resultant (N) | Mean (MPa) | Max patch (MPa) | Area CV |
|---|---|---|---|---|
| Four patches | 1000 | 0.1 | 0.15 | 0.3535534 |
| Uniform | 1000 | 0.1 | 0.1 | 0 |
Equal force and mean do not imply equal spatial concentration.
What the result means for a model
Integrate pressure with area weights and compare to the transmitted force. For a sensor comparison, average over the sensor footprint and resolution; comparing one FE point to an area-averaging sensor introduces a measurement mismatch.
Another application: A smaller contact patch raises the contact-area mean
A 1000 N force over the nominal 10000 mm² face averages 0.10 MPa. If only 5000 mm² is actually in contact, the mean over that contact area is 0.20 MPa. Both values can be correct if their area definitions are stated; neither determines the local maximum.
Further modeling details
Choose the averaging area
Distinguish nominal full-face area from active contact area. If only half a nominal face carries force, the active-area average is twice the nominal-area average. Neither is wrong if labeled; mixing the denominators creates an artificial disagreement between models or tests.
Integrate using compatible data
For a flat interface with parallel normals, pressure times area gives the normal resultant. Do not sum pressure values without area weights, and do not count overlapping nodal areas twice. For curved interfaces, integrate traction vectors in a common coordinate frame; scalar pressure integrals and global force components are not interchangeable.
Understand numerical output
Contact output can be extrapolated, averaged or stored at a particular surface position. Solver-reported contact area also has formulation-dependent approximations. Compare directly reported contact force with support reactions before attempting to reconstruct it from a colored contour. Record the exact field and extraction method.
Compare like-sized measurements
A sensor integrates over a finite footprint and may alter contact by its thickness or stiffness. Map the FE field to the same footprint, orientation and time window. A peak at one node cannot be directly compared to a sensor average. Calibration range and saturation determine whether the measured peak is even observable.
Use a small set of complementary outputs
Track resultant, active contact area, a defined area percentile and a spatial map. CVA is only a descriptive metric and becomes unstable near zero mean pressure. A lower CV does not prove safety if every location exceeds the applicable material limit. Endplate bending and pad layout should be examined spatially when uniformity matters.
Formula and symbol reference
Open the complete formula reference
| Symbol | Meaning | Unit / convention |
|---|---|---|
| pi, Ai | Patch pressure and its nonoverlapping area | MPa; mm² |
| Ac, As | Chosen contact area and sensor footprint | mm² |
| Fn, p̄, CVA | Normal resultant, area mean and coefficient of variation | N; MPa; dimensionless |
When this example stops applying
Piecewise constant synthetic pressures on a flat surface. No sensor transfer function, actual cell pressure limit or spatial FE solution is inferred from this example. Area-weighting requires suitable nonoverlapping integration data.
Check your interpretation
Can two models with identical total normal force have different pressure risk?
Show the reasoning
Yes. Their active areas and spatial distributions can differ. Compare local loading with a relevant material criterion and a consistent extraction method rather than using force alone.
Sources and calculation scope
- Abaqus 2025 · General contact, force and area outputs
- Abaqus 2025 · Field output positions and averaging
The questions and comparison tables are independently authored teaching examples. Numbers illustrate the stated models; they are not measured cell/pack data or commercial-solver validation.
Comparison calculations (Python)
English / Korean · revised 1 November 2026