← All theory chapters
Theory / Contact & Connections

Swelling, Pads & Housing Constraint

Connect imposed free expansion to reaction force and actual stack displacement.

Theory · Educational notes

Where does free cell growth go inside a housing?

A 120 mm stack has E = 100 MPa, area 10000 mm² and free strain 1%. Use housing stiffness 10000 N/mm, without pads, gap or preload.

The free growth must equal housing opening plus compression of the cells relative to their free state. The same force acts through both compliances. Add the compliances before calculating force; adding their stiffnesses would describe a different load path.

Connect the physical quantities

Treat free swelling as a prescribed stress-free change in length. The enclosure allows some of this change, and the remaining part is accommodated by elastic compression relative to that free state. The same axial force passes through series components; their individual displacements add.

The relationship used in this example

Cstack=HEA+∑itiEiAiC_{\mathrm{stack}}=\frac{H}{EA}+\sum_i\frac{t_i}{E_iA_i}

Free swelling acts like an imposed strain. The constrained stack shares displacement between elastic cell compression, pad compression and housing expansion. The force follows compatibility and equilibrium. Electrical series/parallel wiring is unrelated to this mechanical series-compliance calculation.

Work through the example

Step 1

Free growth is Hεfree = 120×0.01 = 1.2 mm.

Step 2

Cell-stack stiffness is EA/H = 8333.33 N/mm. Series compliance is 1/8333.33 + 1/10000 = 0.00022 mm/N.

Step 3

Force is 1.2/0.00022 = 5454.55 N; housing motion 0.54545 mm plus relative cell compression 0.65455 mm closes the budget.

Full example conditions and reference values

For H = 120 mm, E = 100 MPa, A = 10,000 mm², εfree = 0.01 and K = 10,000 N/mm, with no pads, Δfree = 1.2 mm, F = 5,454.55 N and Δhousing = 0.54545 mm. Cell compression relative to free expansion is 0.65455 mm; the two displacements sum to 1.2 mm.

Compare the numbers before judging the result

Compare the calculated values
ConditionForce (N)Housing opening (mm)Cell compression (mm)
K=10000 N/mm5454.5450.54545450.6545455
Rigid housing1000001.2

Opening plus compression always equals the prescribed 1.2 mm free growth.

What the result means for a model

Adding identical cells increases free growth but reduces stack stiffness because H increases. A perfectly rigid enclosure without pads gives F = EAεfree, independent of N in this ideal model. A 1D average cannot identify edge pressure, pouch bulging or plate bending.

This balance uses cell compression measured relative to its freely swollen state. Mixing that value with displacement from the assembled state double-counts part of the motion. Record the reference state beside every displacement output.

Another application: Close the displacement budget

For the no-pad example, 0.65455 mm of cell compression plus 0.54545 mm of housing opening equals 1.2 mm free growth. Making the housing rigid changes the split to 1.2 mm and zero; force rises to 10,000 N. Free growth stays unchanged in this imposed-strain model.

Formula and symbol reference

Open the complete formula reference
H=NLH=NL
Δfree=Hεfree\Delta_{\mathrm{free}}=H\varepsilon_{\mathrm{free}}
Cstack=HEA+∑itiEiAiC_{\mathrm{stack}}=\frac{H}{EA}+\sum_i\frac{t_i}{E_iA_i}
F=ΔfreeCstack+1KF=\frac{\Delta_{\mathrm{free}}}{C_{\mathrm{stack}}+\dfrac1K}
Δhousing=FK\Delta_{\mathrm{housing}}=\frac FK
SymbolMeaningUnit / convention
N, L, HCell count, single-cell thickness and stack thicknesscount; mm; mm
E, ACell through-thickness modulus and loaded areaMPa; mm²
ti, Ei, AiPad thickness, modulus and loaded areamm; MPa; mm²
KHousing stiffnessN/mm
CstackCell/pad series compliancemm/N

When this example stops applying

This example assumes full contact, linear small strain, no initial gap and no preload. As K tends to zero, F tends to zero and the housing displacement tends to Δfree; evaluate that limit directly rather than dividing by zero. Rigid housing with compliant pads still permits cell expansion into pad compression. Pressure distributions require a spatial model.

Check your interpretation

With identical cells, no pads and perfectly rigid housing, does doubling N double the force?

Show the reasoning

No. F = EA εfree is independent of N in this particular uniform linear model. Free stack expansion doubles but stack stiffness halves.

Sources and calculation scope

The questions and comparison tables are independently authored teaching examples. Numbers illustrate the stated models; they are not measured cell/pack data or commercial-solver validation.

Comparison calculations (Python)

English / Korean · revised 1 November 2026