What else changes when mass makes a calculation faster?
Use m = 1 kg and k = 10000 N/m, then multiply mass by four. Compare the natural frequency and the undamped harmonic particular response to 10 N at 80 rad/s.
Larger mass lowers characteristic frequency and can permit a larger explicit stability increment. It also changes the inertia term in the response denominator. In this example the excitation crosses from below to above resonance, so response phase changes as well as magnitude.
A faster step changes the inertia model
Mass scaling modifies numerical mass to increase the explicit stable increment. It does not make stiffness or contact computation free of error. A target step twice as large requires roughly four times the controlling elastic element density under unchanged stiffness and length. This local estimate is not the added mass percentage of the entire pack.
Derive the cost and frequency changes
Wave speed varies as 1/sqrt(ρ), so the transit estimate grows as sqrt(s) when density is multiplied by s. For uniform mass scaling with unchanged stiffness, modal frequencies decrease by 1/sqrt(s). Inertia force at prescribed acceleration grows by s. These simple relations assume the same controlling formulation; evolving geometry and selective mass changes require the actual mass map and diagnostics.
The same force can give a different amplitude and phase
Use k=10000 N/m, original m=1 kg and harmonic force amplitude F0=10 N at Ω=80 rad/s, or 12.732 Hz. Compare the particular harmonic response without free vibration; no damping is included, and the forcing is off resonance for both cases. Original dynamic stiffness is 10000−1×80²=3600 N/m, giving 2.77778 mm in phase with the force. With mass multiplied by four, it is −15600 N/m, giving 0.641026 mm with a 180° phase reversal.
| Mass (kg) | Natural f (Hz) | CDM bound (s) | Harmonic |U| (mm) |
|---|---|---|---|
| 1 | 15.9155 | 0.020 | 2.77778 |
| 4 | 7.95775 | 0.040 | 0.641026 |
Why matching static response is insufficient
Both masses give the same static displacement F0/k=1 mm. Thus a static comparison alone would miss the frequency, amplitude and phase changes above. The fourfold mass change is deliberately large to expose the mechanism; it is not a recommended setting. A target stable increment is a performance control, not an accuracy specification.
For a nonlinear quasi-static model, fixing physical duration preserves the specified material time scale but still changes inertia. Increasing duration and mass simultaneously can conceal compensating errors. Use an unscaled or lower-scaled reference first, then vary only the selected mass setting.
Compare the numbers before judging the result
| Mass (kg) | fn (Hz) | Signed particular amplitude (mm) | CDM stability boundary (s) |
|---|---|---|---|
| 1 | 15.91549 | 2.777778 | 0.02 |
| 4 | 7.957747 | -0.6410256 | 0.04 |
The minus sign indicates a 180° phase reversal of the undamped harmonic particular solution, not a negative amplitude magnitude or a settling transient.
A comparison matrix for a pack
Record the selected element sets, initial added mass and its evolution. Abaqus distinguishes fixed and variable element mass scaling and contact mass scaling; these are different controls. Check the installed version rather than translating keyword signs between solvers. Inspect the controlling elements before modifying density, since bad geometry or a unit error may be the true bottleneck.
Compare reference, mild and stronger scaling with identical mesh, material, contact, load duration and output. Track runtime only alongside force–displacement, impulse, acceleration, local contact and deformation sequence. Added mass in a small fastener region may barely affect total pack mass yet significantly change a local mode or force path.
No universal safe percentage
The single-DOF formulas do not predict selective scaling of a multi-mode pack. Total mass percentage cannot establish unchanged inertia tensor, mode shape, contact force or crash pulse. Define tolerances for the actual quantities of interest and verify them against the reference; do not infer acceptance from a small global percentage alone.
What must be retained in the record?
Keep original densities, changed regions, mass history, actual increment history, load duration and comparison traces. If natural frequency halves while the static displacement matches, a fourfold uniform mass increase explains both observations in the simple model. It is not evidence that stiffness calibration improved.
Sources & reproduction
The official references document algorithms and solver scope. Derivations, examples and figures here are independently constructed for the stated assumptions. Numerical checks do not replace battery tests or commercial-solver verification.
- Abaqus 2025 · Mass Scaling — fixed, variable and contact mass scaling
- Abaqus 2025 · Explicit Dynamic Analysis — stability and constraints
Only the Python 3 standard library is required. Download the code and run the command below to generate CSV files and verification results in a new folder.
python3 reproduce.py --out results- Calculation code (Python)
- Newton iterations (CSV)
- Discrete frequencies (CSV)
- CDM time history, h = 0.005 s
- Newmark time history, h = 0.005 s
- Force-ramp response (CSV)
English and Korean share equations, examples, figures and section coverage. Revised 1 November 2026.