← All theory chapters
Theory / FEM

Time Step, Increment & Output Sampling

Separate integration stability, time accuracy and saved-output sampling with computed examples.

Theory · Educational notes · Related tools: Abaqus · LS-DYNA

Was the event never solved, or merely never saved?

Use a half-sine pulse lasting 1 ms with unit peak. Compare stored samples every 1 ms and every 0.25 ms before considering the solver integration increment.

The solver may take many small increments between output frames. Sparse output can hide a peak even when integration is accurate. Conversely, dense output cannot repair an inaccurate integration. Keep sampling, stability and temporal accuracy as separate questions.

Three independent resolutions

The integration increment advances the solution; the output interval samples the saved response; the frequency grid samples a spectrum. Dense output cannot repair a poorly integrated trajectory, while a well-integrated impact can still lose its peak in sparse output. Record all three where applicable.

Where the explicit bound comes from

For a constant-step undamped linear system, diagonalizing the equations into modes gives the CDM scalar bound h<2/ωmax. This is a stability condition, not a target accuracy. A characteristic element transit time Lchar/cd is an estimate used to understand the cost; element shape, constitutive stiffness, constraints, damping and contact can change the actual solver estimate.

For an isotropic elastic continuum use the dilatational wave speed below. The bar estimate sqrt(E/ρ) describes a different idealization. Kb denotes bulk modulus, not a structural stiffness. Lchar is formulation-dependent and should not automatically be replaced by the shortest visible mesh edge.

hcrit=2ωmax⁡(undamped linear CDM)h_{\rm crit}=\frac2{\omega_{\max}}\quad\text{(undamped linear CDM)}
cd=Kb+4G/3ρ,hest≈Lcharcdc_d=\sqrt{\frac{K_b+4G/3}{\rho}},\qquad h_{\rm est}\approx\frac{L_{\rm char}}{c_d}
Kb=E3(1−2ν),G=E2(1+ν)K_b=\frac{E}{3(1-2\nu)},\qquad G=\frac{E}{2(1+\nu)}

Compute the cost estimate, then its limits

Take E=70 GPa, ν=0.33 and ρ=2700 kg/m³. Kb≈68.627 GPa, G≈26.316 GPa and cd≈6198 m/s. A 1 mm characteristic length gives about 0.161 μs; 0.2 mm gives 0.0323 μs. Over 20 ms these fixed estimates imply roughly 124000 and 620000 increments. This is a scaling calculation; it does not predict an evolving crush mesh step by step.

Compare accuracy at the same physical times

Use the free oscillator in Implicit & Explicit: ω=100 rad/s and period 0.062832 s. With h=0.019 s there are only 3.31 increments per period. The discrete frequencies below quantify the accumulated phase error even though CDM is below its stability limit. Compare displacement at common times and peak timing, not row number in two files with different increments.

Compare accuracy at the same physical times
Δt (s) CDM ω (rad/s) Newmark ω (rad/s)
0.019131.9195779.97503
0.005101.0721097.99147
0.001100.0417199.91679

Compare the numbers before judging the result

Compare the calculated values
Saved time (ms)Unit half-sine
00
0.250.7071068
0.51
0.750.7071068
11.2246e-16

Saving only the first and last rows hides the entire pulse. Sampling phase also matters.

An integrated pulse can disappear from output

Let p(t)=sin(πt/0.001) on 0≤t≤1 ms and zero afterward. Its true peak is 1 at 0.5 ms. Output at 0, 1 and 2 ms contains only zero. Sampling every 0.25 ms captures this particular peak, but shifting the grid by 0.125 ms gives a maximum sin(3π/8)=0.923880, 7.61% low. Sampling density and alignment both matter.

A practical comparison uses a dense reference history, then independently coarsens integration and output. For a narrow impact peak record force history at the relevant interface; field animation frames can be less frequent. Retain raw data before filtering and state the filter bandwidth and phase behavior. Nyquist alone is not a transient-peak error bound.

Keep automatic stepping visible

An implicit cutback can be driven by nonlinear convergence or accuracy controls; it is not the same as an explicit wave-speed bound. Exact-output-time controls can also affect stepping in some procedures. Inspect actual increments, critical elements and the event at which they change. Mesh refinement reduces spatial error but can increase explicit cost by reducing the step as well as increasing the number of elements.

Two checks, not one

A force peak grows when output becomes denser but the integration increment is unchanged. This identifies a sampling effect, not proof of integration convergence. Next hold output sufficiently dense and refine integration. Compare peak, impulse and timing, since they need not converge at the same rate.

Sources & reproduction

The official references document algorithms and solver scope. Derivations, examples and figures here are independently constructed for the stated assumptions. Numerical checks do not replace battery tests or commercial-solver verification.

Only the Python 3 standard library is required. Download the code and run the command below to generate CSV files and verification results in a new folder.

python3 reproduce.py --out results

English and Korean share equations, examples, figures and section coverage. Revised 1 November 2026.