How much SOC does a known current remove?
Discharge a 5 Ah cell at 2.5 A for 0.5 h, starting at SOC 80%. Assume constant usable capacity and ideal charge counting. Find the final SOC.
Current times time gives removed charge, not SOC directly. Divide by usable capacity to obtain the fraction removed. Subtract percentage points from the initial SOC; terminal voltage also includes polarization and cannot be substituted for this charge balance.
Connect the physical quantities
Ampere-hours measure charge, while watt-hours measure energy. Coulomb counting updates a charge fraction; it does not determine terminal voltage by itself. The voltage also reflects electrode state, temperature, current-related losses and concentration gradients.
The relationship used in this example
Lithium-ion cell operation combines ionic transport, electronic transport and interfacial reactions. SOC is an inventory measure referenced to a defined usable capacity. Equilibrium full-cell voltage is the difference between positive and negative electrode equilibrium potentials. Under load, polarization makes terminal voltage different from equilibrium voltage.
Work through the example
Removed charge is 2.5 A×0.5 h = 1.25 Ah.
Divide by usable capacity 5 Ah: SOC drop is 0.25, or 25 percentage points.
Subtract from initial fraction: 0.80−0.25 = 0.55. It is not 80% reduced by 25% of itself.
Full example conditions and reference values
For a 5 Ah cell discharged at 2.5 A for 0.5 h, the removed charge is 1.25 Ah and the ideal SOC decrease is 0.25. Starting at SOC = 0.80 gives SOC = 0.55, assuming constant usable capacity and unity coulombic efficiency.
Compare the numbers before judging the result
| Capacity (Ah) | Removed (Ah) | Final SOC (%) |
|---|---|---|
| 5 | 1.25 | 55 |
| 4 | 1.25 | 48.75 |
The same removed charge is a larger fraction of a smaller usable capacity.
What the result means for a model
For a mechanical coupling model, SOC is an input coordinate for a calibrated expansion law, not a strain value. Define the SOC reference and usable capacity before mapping it to deformation. Capacity changes with condition can otherwise appear as a false shift in the swelling curve.
When mapping SOC into swelling, use the same capacity convention and reference state as the expansion data. Do not shift the swelling curve simply to compensate for an uncorrected initial SOC error.
Another application: A capacity assumption changes the SOC estimate
Removing 1.25 Ah from a 5 Ah capacity corresponds to a 25 percentage-point SOC drop. With a separately established usable capacity of 4 Ah, the same charge corresponds to 31.25 percentage points. Starting at 80% gives 55% and 48.75%, respectively, under the stated ideal assumptions.
Formula and symbol reference
Open the complete formula reference
| Symbol | Meaning | Unit / convention |
|---|---|---|
| I | Current, positive for discharge in this note | A |
| t | Time | s |
| Qₙ | Reference usable capacity | Ah |
| SOC | State of charge, as a fraction | 0–1 |
| U | Equilibrium potential or cell voltage | V |
When this example stops applying
Coulomb counting does not estimate capacity fade by itself. Initial SOC error accumulates through the calculation. A simple SOC balance is not a spatial concentration model. OCV–SOC relations depend on chemistry, temperature and history; voltage under load cannot be interpreted as OCV.
Check your interpretation
Is 50% SOC equivalent to half the maximum cell voltage?
Show the reasoning
No. Voltage follows electrode thermodynamics and polarization, not a linear scaling with remaining charge.
Sources and calculation scope
The questions and comparison tables are independently authored teaching examples. Numbers illustrate the stated models; they are not measured cell/pack data or commercial-solver validation.
Comparison calculations (Python)