Why does a softening law need an energy scale?
Let traction decrease linearly from 100 MPa to zero over 0.2 mm separation. Compute energy per crack area and then energy for a specified crack area.
The area under traction–separation is energy per area. Multiplying by crack area gives total energy. A strain-softening law needs a length to convert localized strain into opening; otherwise changing element size can change dissipated energy without changing the entered curve.
Connect the physical quantities
Initiation identifies when degradation starts; evolution specifies how load capacity is lost afterward. Energy per crack area can help regularize the softening response as mesh size changes. It does not automatically remove every mesh or localization dependence.
The relationship used in this example
A damage initiation criterion identifies a threshold. An evolution law controls softening after that threshold. Element deletion is a numerical treatment at a specified state; it is not itself a physical fracture law.
Work through the example
Triangle area is 0.5×100 MPa×0.2 mm = 10 N/mm.
For an assumed 20 mm² crack area, this law would dissipate 200 N·mm = 0.2 J.
At scalar damage d = 0.25, (1−d)×100 = 75 MPa for the stated effective stress.
Full example conditions and reference values
For a synthetic triangular softening curve beginning at t₀ = 100 MPa and ending at zero traction after an additional separation uf = 0.2 mm, Gf = 10 N/mm. This is energy per crack area, not total specimen energy. Under the illustrative scalar law, d = 0.25 reduces an effective stress of 100 MPa to 75 MPa.
Compare the numbers before judging the result
| Crack area (mm²) | Gf (N/mm) | Total energy (J) |
|---|---|---|
| 20 | 10 | 0.2 |
| 100 | 10 | 1 |
Multiply energy per area by the area; 1000 N·mm equals 1 J.
What the result means for a model
Keep traction–separation units distinct from stress–strain input. In a smeared continuum model, characteristic length participates in the conversion. Check force–displacement work, localization width and deletion energy under mesh changes; do not compare failure strain alone.
Compare force–displacement work and the damaged-zone width across meshes. The same failure strain on smaller elements can change dissipated energy. Energy regularization addresses that dependence but does not prove the crack path or material calibration is correct.
Another application: Keep fracture energy tied to an area
The triangular traction–separation example gives 10 N/mm. If the same law acts uniformly over a 100 mm² crack area, the dissipated energy is 1,000 N·mm = 1 J. Applying a stress–strain softening curve instead requires a characteristic length to relate strain localization to separation.
Further modeling details
Why softening needs a length scale
If the same stress–strain softening law localizes in one element, changing element size changes the energy dissipated by the crack band. Displacement- or energy-based descriptions introduce a characteristic length to control that dependence.
A useful comparison sequence
Hold geometry, loading and material parameters fixed. Compare multiple meshes using force–displacement, dissipated energy, failure location and deformation pattern. A matched peak load alone is insufficient.
EV enclosure application
For a torn housing or bracket, distinguish material rupture from joint separation and contact release. Preserve the original test curve and compare the failure path before changing erosion or damage parameters.
Formula and symbol reference
Open the complete formula reference
| Symbol | Meaning | Unit / convention |
|---|---|---|
| d | Illustrative scalar damage variable | 0 to 1 |
| σ̃, σ | Undamaged effective stress; degraded stress | MPa |
| t0, uf | Peak traction; post-initiation separation at failure | MPa; mm |
| Gf | Area under traction–separation softening curve | N/mm |
When this example stops applying
The scalar degradation equation is illustrative, not a universal material implementation. Characteristic-length regularization reduces one source of mesh sensitivity but does not prove mesh objectivity. Mixed-mode fracture, stress state, rate and loading path can require additional laws.
Check your interpretation
Can a damage initiation value alone define the complete force drop?
Show the reasoning
No. The post-initiation evolution and any deletion settings also control the response.
Sources and calculation scope
The questions and comparison tables are independently authored teaching examples. Numbers illustrate the stated models; they are not measured cell/pack data or commercial-solver validation.
Comparison calculations (Python)
English / Korean · revised 1 November 2026