← All theory chapters
Theory / Thermal & Electrochemical

Cell–Module–Pack Model Transfer

Transfer a defined response between model levels while checking reference states, force, moment and work.

Theory · Educational notes

What must be preserved when moving to a coarser assembly model?

Stack four 2000 N/mm cells, each growing freely by 0.20 mm. Add pad compliance 0.001 mm/N and housing stiffness 1000 N/mm.

Mechanical series cells share force and add compliance and free growth. A coarser representation must preserve these relations. For spatial interfaces, preserving only total force can lose moment or virtual work, so the required outputs determine how much detail can be condensed.

Connect the physical quantities

The relationship used in this example

F=ΔfreeCcell+Cpad+1/KF=\frac{\Delta_{\mathrm{free}}}{C_{\mathrm{cell}}+C_{\mathrm{pad}}+1/K}

A cell model supplies responses under stated conditions, such as free thickness growth and compression compliance. The module or pack imposes restraint through pads, plates and joints. Transfer these quantities with their reference state and solve the assembly compatibility; copying a cell force curve without its fixture condition can assign the fixture effect to the cell twice.

Work through the example

Step 1

Add series cell compliance: 4/2000 = 0.002 mm/N. Add pads and housing: 0.002+0.001+1/1000 = 0.004 mm/N.

Step 2

Compute force: (4×0.20)/0.004 = 200 N. Recover the three contributions: 0.40, 0.20 and 0.20 mm.

Step 3

Check the independent mapping example: force 400 N, moment −50×100+50×300 = 10,000 N·mm, virtual work 100 N·mm.

Full example conditions and reference values

Synthetic assembly: four identical cells are stacked in series, each with stiffness 2000 N/mm and free growth 0.20 mm. Total pad compliance is 0.001 mm/N and housing stiffness is 1000 N/mm. Total free growth is 0.80 mm, cell compliance 0.002 mm/N and total compliance 0.004 mm/N. Equilibrium force is 200 N. Cell compression relative to free growth is 0.40 mm, pad compression 0.20 mm and housing expansion 0.20 mm; these sum to 0.80 mm.

Cell–Module–Pack Model Transfer — original educational diagram
Original Jaylab teaching diagram. Synthetic values; not measured cell or pack data.

Compare the numbers before judging the result

Compare the calculated values
Cells in seriesCell-stack k (N/mm)Free growth (mm)Force with same pads/housing (N)
120000.280
210000.4133.3333
45000.8200

Cell count changes both free growth and cell compliance. Holding only one of those changes would describe a different assembly.

What the result means for a model

Transfer the reference area, thickness direction and preload with the reduced response. A cell curve measured under one fixture cannot be used as a free-growth curve unless its restraint effect has been removed or explicitly retained in the assembly model.

Another application: Mechanical stacking is not electrical wiring

Four identical 2000 N/mm cells in mechanical series have stiffness 500 N/mm, and four 0.20 mm free expansions add to 0.80 mm. Wiring those cells electrically in parallel would not change this axial-compliance calculation if the physical stack and boundary conditions stayed the same.

Further modeling details

Define a compact transfer record

For each transferred curve or field, record units, axes, sign, reference dimensions, SOC, temperature, history, loading rate, spatial averaging and applicable range. Specify whether displacement is measured from the free, assembled or preloaded state. A total thickness curve and an incremental growth curve cannot be interchanged without a reference conversion.

Separate material modulus from assembly stiffness

A modulus has units N/mm²; a force–displacement slope has units N/mm. Converting through k = EA/L requires a justified uniform axial model. In this example four identical series cells have stiffness 500 N/mm, not 8000 N/mm. The parallel sum describes a different load path. Actual pouch compression data may also contain lateral constraint and fixture effects.

Close the displacement budget

At 200 N, each cell compresses 0.10 mm relative to its freely grown state. Its net thickness increase is therefore 0.20−0.10 = 0.10 mm. Four cells grow by 0.40 mm; pads shorten by 0.20 mm; the enclosed stack grows by 0.20 mm, matching the housing. Do not add pad compression as an extra positive stack growth.

Preserve moment as well as total force

In a separate two-point example, upward forces 100 and 300 N act at x = −50 and +50 mm. The total is 400 N and the moment about the center is 10,000 N·mm. Replacing them by a 400 N center force preserves force but removes the moment. A rigid-body equivalent needs both the center force and the couple; a flexible surface may need a richer distribution.

Use virtual work to catch a lost rotation

Give those points upward virtual displacements 0.10 and 0.30 mm. Their virtual work is 100×0.10+300×0.30 = 100 N·mm. The equivalent translation is 0.20 mm and small rotation 0.002 rad: 400×0.20+10,000×0.002 = 100 N·mm. Using only the center translation gives 80 N·mm. This check tests mapping consistency, not real energy dissipation or validation.

Distinguish one-way submodeling from feedback

A global-to-local submodel uses a global solution to drive a refined region. It is useful when the local refinement does not significantly alter the global response. If local cracking, pad relaxation or contact opening changes the assembly load path, a one-way transfer may no longer suffice. Recompute or couple the levels and check consistency instead of prescribing incompatible forces and displacements on the same degrees of freedom.

Verify at each level

First reproduce a cell curve under its own test conditions, then an assembly force–displacement response, then the pack outputs relevant to the intended load. Track mass and inertia separately for dynamics; the static stiffness example contains neither. A correct 1D budget is a prerequisite, not proof that a three-dimensional contact-pressure field or crash result is accurate.

Formula and symbol reference

Open the complete formula reference
Ccell=∑i1kiC_{\mathrm{cell}}=\sum_i\frac{1}{k_i}
F=ΔfreeCcell+Cpad+1/KF=\frac{\Delta_{\mathrm{free}}}{C_{\mathrm{cell}}+C_{\mathrm{pad}}+1/K}
ΔH=FK\Delta_H=\frac{F}{K}
Δfree=FCcell+FCpad+ΔH\Delta_{\mathrm{free}}=FC_{\mathrm{cell}}+FC_{\mathrm{pad}}+\Delta_H
F=∑ifi,M=∑iri×fi\mathbf F=\sum_i\mathbf f_i,\quad\mathbf M=\sum_i\mathbf r_i\times\mathbf f_i
δW=∑ifi⋅δui\delta W=\sum_i\mathbf f_i\cdot\delta\mathbf u_i
SymbolMeaningUnit / convention
ki, KCell axial stiffness; housing restraint stiffnessN/mm
Ccell, CpadSeries compliance of cells; total series pad compliancemm/N
Δfree, ΔHFree stack growth; housing displacement from the stated referencemm
F, fi, MCompression magnitude; mapped force vectors; resultant momentN; N; N·mm
δW, δuiVirtual work; virtual displacementN·mm; mm

When this example stops applying

The assembly is small-strain, linear, quasistatic and initially unpreloaded, with maintained full-face contact and no gaps. Pads are represented by a total series compliance. The mapping example assumes small rigid-body virtual motion. Nonlinear hysteresis, evolving contact, spatial homogenization and thermodynamic coupling require additional models.

Check your interpretation

What is lost when a distributed interface load is replaced only by its total force at the center?

Show the reasoning

The moment and deformation-dependent work can be lost. Preserve the force and moment for rigid-body equivalence, then check whether the retained degrees of freedom are sufficient for the local flexible response.

Sources and calculation scope

The questions and comparison tables are independently authored teaching examples. Numbers illustrate the stated models; they are not measured cell/pack data or commercial-solver validation.

Comparison calculations (Python)