← All theory chapters
Theory / Verification & Correlation

Test–Analysis Correlation & Model Updating

Compare matching observables before changing model parameters.

Theory · Educational notes · Related tools: Abaqus · LS-DYNA

What does a good match actually mean?

Compare 100 Hz measured and 105 Hz predicted frequency. Separately compare forces [0,100,200] and [0,110,180] N at the same displacement samples.

Frequency error, mode-shape similarity and force residual measure different features. Align coordinates and sampling before calculating an error. Changing stiffness can align one frequency while compensating for a mass or boundary error, so retain an independent observable for checking the update.

Connect the physical quantities

Frequency agreement, shape agreement and amplitude agreement answer different questions. A model can produce a similar mode shape while being too stiff. Correlation starts by matching coordinates, units, sensor locations and boundary conditions before changing material parameters.

The relationship used in this example

RMSE=1n∑i=1n(yi−y^i)2\mathrm{RMSE}=\sqrt{\frac1n\sum_{i=1}^n(y_i-\hat y_i)^2}

Compare the same load, support condition and measured quantity before adjusting parameters. Frequency, mode shape and force–displacement error describe different mismatches. A parameter update should improve the intended responses together and then be checked against a case that was not used for fitting.

Work through the example

Step 1

Frequency error is (105−100)/100 = +5%.

Step 2

Force residuals at shared samples are [0,10,−20] N.

Step 3

RMSE = √((0²+10²+20²)/3) = 12.91 N; divide by 200 N range for 6.455%.

Full example conditions and reference values

Using synthetic data, ftest = 100 Hz and fFE = 105 Hz give +5% frequency error. Mode vectors [1, 2, 1] and [1, 1.8, 1.1] give MAC = 0.99358. Separately, measured forces [0, 100, 200] N and predicted [0, 110, 180] N at identical displacement samples give RMSE = 12.91 N and range-normalized RMSE = 6.455%. High shape similarity does not remove the frequency or force discrepancy.

Two normalized three-coordinate mode vectors almost overlap; the caption highlights that frequency disagreement remains despite high MAC.
The plotted vectors are unit-normalized for display. High shape similarity does not remove the independently specified 100 Hz versus 105 Hz frequency difference.

Compare the numbers before judging the result

Compare the calculated values
SampleObserved (N)Predicted (N)Residual (N)
1000
210011010
3200180-20

Compute RMSE from squared residuals at matched samples; their signed average would allow cancellation.

What the result means for a model

Use withheld conditions to check whether a tuned model generalizes. A frequency-only fit can trade off mass and stiffness. Report residual patterns and measurement uncertainty rather than hiding systematic bias behind one aggregate score.

Keep at least one independent load case out of calibration. Compare sensor coordinates, support conditions and filtering before optimization; otherwise the optimizer can compensate for a mismatch in the test definition.

Another application: A good fit on one case can hide a wrong parameter

If a model is 5% high in frequency and mass is assumed correct, scaling stiffness by (1/1.05)² ≈ 0.907 could align that frequency. The same correction may spoil a static-deflection match or another mode. The algebra does not prove that stiffness was the original error.

Further modeling details

Align before scoring

Match sensor coordinates, directions, units, sign conventions and fixture conditions. For transients, document time alignment and filtering; for force–displacement, define interpolation and the evaluated range. Do not choose a convenient shift only to improve a score.

Choose complementary observables

Compare natural frequencies and modal shapes together. For a crush test, compare loading stiffness, peak force, work, deformation mode and failure location. A single scalar error cannot represent all engineering behaviors.

Update identifiable parameters

Use physically plausible bounds and parameter sensitivity. Several combinations of joint stiffness and material modulus may fit one frequency. Add independent observables to distinguish them rather than accepting a numerically perfect but non-unique fit.

Keep a validation ledger

Save the original prediction, each parameter change and its rationale. Separate calibration cases from held-out cases. Record uncertainty from tests, geometry and material scatter, and state the range of conditions for which evidence exists.

Write a measurement-to-output contract

For each comparison state the physical quantity, location, direction, units, reference state, sampling, averaging and filtering. A load-cell resultant is not a single nodal reaction, and a sensor-footprint average is not a maximum contour value. If several supports carry load, sum compatible vector components with a declared sign convention.

Example: a sensor covers two unequal patches

On a synthetic flat interface, two nonoverlapping patches have areas 1000 and 3000 mm² with pressures 0.20 and 0.10 MPa. The resultant is 200+300 = 500 N and an ideal sensor covering both reports 500/4000 = 0.125 MPa. The arithmetic mean of the two pressures is 0.15 MPa, which is 20% higher; the peak 0.20 MPa is 60% higher. Neither difference establishes a material-model error because the compared quantities differ.

Separate spatial recovery from physical variability

Record whether stresses are integration-point values, extrapolated nodal values or averaged display values. Across a material interface, automatic averaging can hide a jump. Extract the field at the intended physical support and use compatible weights. A higher mesh peak does not automatically improve the comparison with a finite-sized gauge.

Time alignment is a documented operation

Compare signals on a common time base and record trigger offsets, interpolation, anti-alias filtering and bandwidth. Filtering can change a transient peak and phase, so retain raw and processed signals and apply a justified comparable procedure. An optimized time shift chosen only to reduce error is a fitted parameter, not independent agreement.

Compare global and local evidence together

Start with force and moment balance, then compare displacement, spatial strain/pressure and failure location. If global force agrees but pressure is concentrated at the wrong edge, tuning a modulus alone may be misleading. Keep calibration and holdout conditions separate; report discrepancies and uncertainty rather than declaring success from one overlay.

Formula and symbol reference

Open the complete formula reference
δf=fFE−ftestftest\delta_f=\frac{f_{\mathrm{FE}}-f_{\mathrm{test}}}{f_{\mathrm{test}}}
MAC=∣ϕHψ∣2(ϕHϕ)(ψHψ)\mathrm{MAC}=\frac{|\boldsymbol\phi^H\boldsymbol\psi|^2}{(\boldsymbol\phi^H\boldsymbol\phi)(\boldsymbol\psi^H\boldsymbol\psi)}
RMSE=1n∑i=1n(yi−y^i)2\mathrm{RMSE}=\sqrt{\frac1n\sum_{i=1}^n(y_i-\hat y_i)^2}
NRMSE=RMSEymax⁡−ymin⁡\mathrm{NRMSE}=\frac{\mathrm{RMSE}}{y_{\max}-y_{\min}}
SymbolMeaningUnit / convention
fFE, ftestMatched numerical and measured mode frequenciesHz
φ, ψMode vectors at common mapped coordinatesconsistent relative response units
HConjugate transpose; transpose for real vectorsoperator
y, ŷMeasured and predicted samples on a common axissame physical unit
NRMSERange-normalized RMSE as defined on this pagedimensionless

When this example stops applying

MAC measures collinearity on the sampled coordinates, not absolute amplitude or damping accuracy. Sparse sensors and close modes can make pairings ambiguous. Frequency error is undefined for zero reference frequency, and range-normalized RMSE is undefined for a constant reference signal. No universal metric threshold establishes validation.

Check your interpretation

If two modes have MAC = 1, must their frequencies and damping match?

Show the reasoning

No. MAC is unchanged by scalar rescaling and evaluates shape alignment, not frequency or damping.

Sources and calculation scope

The questions and comparison tables are independently authored teaching examples. Numbers illustrate the stated models; they are not measured cell/pack data or commercial-solver validation.

Comparison calculations (Python)

English / Korean · revised 1 November 2026