Why can a modest amplitude increase greatly shorten life?
Use an illustrative S–N curve with one million cycles at 100 MPa amplitude and power exponent 5. Compare 100 and 125 MPa, keeping the mean-stress condition fixed.
First distinguish amplitude from the full stress range. The power law acts on amplitude, so a convention error is amplified by the exponent. The resulting number is a model life under the stated cycle condition, not a failure probability.
Connect the physical quantities
An S–N curve is meaningful only with a compatible stress definition, load ratio and material condition. Amplitude is half the range. A steep power law means a modest stress error can cause a large life error, even before scatter is considered.
The relationship used in this example
Fatigue damage can accumulate under repeated loading below the monotonic failure load. An S–N curve relates a defined stress measure to cycles to a defined endpoint. Always identify whether that endpoint is crack initiation, a specified crack size or final failure.
Work through the example
For limits −100 and +100 MPa, range is 200 MPa and amplitude is 100 MPa.
At 125 MPa, use N = 10⁶(100/125)⁵.
The result is 327680 cycles: a 25% amplitude increase leaves about 32.8% of the reference life.
Full example conditions and reference values
A synthetic fully reversed curve has Nref = 1,000,000 cycles at amplitude 100 MPa and slope m = 5. At 125 MPa, the power law gives 327,680 cycles. A cycle from −100 to +100 MPa has amplitude 100 MPa, range 200 MPa, mean zero and R = −1.
Compare the numbers before judging the result
| Amplitude (MPa) | Life (cycles) |
|---|---|
| 100 | 1000000 |
| 125 | 327680 |
| 200 | 31250 |
The 200 MPa row illustrates wrongly entering the full range as amplitude for a ±100 MPa cycle.
What the result means for a model
A weld hot-spot curve is not interchangeable with a polished coupon curve or raw nodal peak stress. State cycles versus reversals and use the appropriate stress measure. The synthetic relation here has no implied endurance limit or reliability percentile.
Write amplitude or range in the column heading, alongside stress units and the curve’s reference load ratio. A curve for a polished specimen cannot be transferred to a welded detail merely because both use MPa.
Another application: Range mistaken for amplitude
The cycle −100 to +100 MPa has amplitude 100 MPa and range 200 MPa. With N = 10⁶(100/σa)⁵, the correct life is 10⁶ cycles. Entering 200 MPa as amplitude gives 31,250 cycles: a factor of 32 error produced only by the input convention.
Further modeling details
From FE stress to fatigue input
Choose the stress measure that matches the fatigue method. A maximum von Mises contour loses the time history and sign information needed by many fatigue methods. For nonproportional multiaxial loading, a single scalar history may be insufficient.
EV bracket example
A module bracket sees road-induced cyclic loading superimposed on assembly loads. Establish the service spectrum, stress history at the relevant location and the material or joint curve before estimating life.
Input checklist
Document surface condition, size effects, stress gradient, temperature, manufacturing route and survival probability. FEMFAT provides method-specific treatments; do not assume every correction is already contained in the base material curve.
Formula and symbol reference
Open the complete formula reference
| Symbol | Meaning | Unit / convention |
|---|---|---|
| σa, σm | Stress amplitude; mean stress | MPa |
| R | Stress ratio when maximum stress is nonzero | dimensionless |
| N, Nref | Life; reference life | cycles |
| m | Positive slope magnitude in this power-law convention | dimensionless |
When this example stops applying
Only use the power law over its fitted range. An endurance limit is not universal. Weld fatigue requires compatible stress definitions and fatigue curves. Significant local cyclic plasticity may require strain–life methods. This example is not a FEMFAT result or component life prediction.
Check your interpretation
Is stress range the same as stress amplitude?
Show the reasoning
No. For a defined cycle, range is twice the amplitude. Confusing them can cause large life errors.
Sources and calculation scope
The questions and comparison tables are independently authored teaching examples. Numbers illustrate the stated models; they are not measured cell/pack data or commercial-solver validation.
Comparison calculations (Python)
English / Korean · revised 1 November 2026