Actual Abaqus numerical campaign · synthetic material/reference · not physical material approval
EXPLORE PUBLISHED SOLVER RESULTS
Compare notch and mesh responses
This viewer selects existing actual Abaqus results. The material/reference are synthetic FE; it does not run new solves or establish physical material approval.
Loading comparison evidence…
Force–Displacement
Inspect displayed points with a pointer, touch or arrow keys on the graph.
Energy history
Full 0–4 ms history, independent of the F-D display interval. Quarter-model energies are scaled ×4 to the full coupon.
Readouts are nearest retained source points, not interpolated values.
Frozen cohort result: geometry check 0/2 · historical check 0/2 · joint identification criteria unmet. Selection and display interval do not change scores or denominators.
| Mesh | F-D nRMSE % | Peak difference % | Separation difference % | Own-peak work difference % | Frozen result |
|---|
Display curves retain chronological bucket minima/maxima, endpoints and event neighbors. No smoothing is applied; these subsets are not used for scoring or integration. Full histories remain in CSV. Faint bands indicate output-frame brackets, not material scatter or confidence intervals.
What was actually executed?
This case asks whether common mesh-effective softening coefficients transfer across different notch geometries. 38 new native Windows Abaqus 6.14-5 solves completed: two new fine references, 32 identification solves and four geometry checks. Two older reference solves were reused. These are not 38 physical tests.
The material and reference responses are a manufactured synthetic FE benchmark, not an experimentally identified alloy or fracture locus. Windows SSH execution is distinct from native GUI validation. Strict acceptance was 0/2 for the held-out geometry and 0/2 for the historical geometry, and joint identification also did not meet all criteria.
Fixed material, specimen and roles
The gauge region is 50×12.5×1 mm, overall length 80 mm, notch depth 2 mm and minimum remaining width 8.5 mm. Parameter a is the axial notch half-length, not the root radius. a=6 and 2 mm are identification shapes, a=4.5 mm is the geometry check with previously unused coarse responses, and a=3 mm is a historical check. Once reviewed, these results cannot be relabeled as unseen data in a later method revision.
The 0.1 mm local in-plane target is compared with h=1 and 2 mm. A transverse quarter-symmetry C3D8R model preserves two divisions across the full thickness. This is not an isotropic 0.1 mm mesh throughout the entire specimen, nor a new full-model symmetry verification. Nominal h is not an extracted solver characteristic length.
The fixed synthetic card uses E=210000 MPa, nu=0.3, density7.85e−9tonne/mm³ and plastic points(stressMPa,p)=(320,0),(420,0.1),(620,0.3),(1320,1). Initiation PEEQ 0.12 and the original 12 N/mm energy anchor remain fixed. Explicit duration 0.004 s, stroke 2 mm, no mass scaling and bulk-viscosity coefficients 0.06/1.2 were unchanged.
Shared correction and a bounded search
Initiation multiplier is locked at 1. Failure plastic-displacement multiplier ku and the shape exponent in D=q^m are shared across both identification shapes at each h. q is normalized plastic displacement. The exponent m is stored as p in the code and is not the plastic-strain p used in the hardening chapter. ku is not a measured Gf multiplier.
The plan fixes eight proposals per h, each requiring both identification solves. It emphasizes the worst normalized response error; missing separation/numerical evidence receives a 100 penalty. The profile is frozen before geometry checks and is not refitted using their scores.
| h mm | Locked onset multiplier | ku | m | Interpretation |
|---|---|---|---|---|
| 1 | 1 | 0.974206032 | 1.286856635 | Research candidate; joint criteria not met |
| 2 | 1 | 1.45 | 1.2 | All proposals received the failure penalty; first proposal retained |
The 2 mm row is not an identified optimum. Failure within eight proposals is also not proof that no mathematical solution exists.
Frozen criteria and the complete cohort
development_mesh_v2 uses F-D nRMSE 10%, peak force 5%, STATUS complete-separation displacement 10% and signed own-positive-peak-to-separation work 15%. Numerical diagnostics and STATUS output-resolution limits of 5% are separate. F-D nRMSE uses 1001 uniformly spaced displacement points over the fixed comparison interval, normalized by the reference force span.
| Geometry | Role | h mm | F-D % | Peak difference % | Separation difference % | Own-peak work difference % | Result |
|---|---|---|---|---|---|---|---|
| a=6 | identification | 1.0 | 29.885 | 0.087 | -8.713 | -53.473 | not accepted |
| a=2 | identification | 1.0 | 8.330 | 1.205 | 4.538 | 58.718 | not accepted |
| a=6 | identification | 2.0 | 10.699 | 1.840 | 0.004 | -10.726 | not accepted |
| a=2 | identification | 2.0 | — | — | — | — | unscored |
| a=4.5 | held-out geometry | 1.0 | — | — | — | — | unscored |
| a=4.5 | held-out geometry | 2.0 | 28.430 | 0.456 | -9.044 | 8.310 | not accepted |
| a=3 | historical check | 1.0 | 38.542 | -1.362 | -11.217 | 39.846 | not accepted |
| a=3 | historical check | 2.0 | 16.044 | 2.108 | 7.494 | 94.420 | not accepted |
The comparison endpoint was fixed from each 0.1 mm reference's last connected STATUS frame. An earlier-separating coarse candidate retains its subsequent ringing inside that fixed interval. Unscored and failed cases remain in the denominator.
Read the actual output curves
The figures derive from completed native ODBs and checked inputs. Forces are scaled to the full specimen. Displacement is RP_RIGHT U 1 relative to the fixed left grip, not automatically an extensometer measurement.








Diagnosed causes and limited development usefulness
a=2 mm,h=2 mm: maximum stored PEEQ 0.107204616 is below the locked onset 0.12 and SDEG remains 0. Evolution coefficients do not activate damage in this loading range. The solved input has−36.338% error in removed-notch area and 0.828427 mm maximum vertical boundary discrepancy. These are not whole-specimen area error or proof that geometry is the only cause. No arbitrary first-damage location was invented for this case.
a=4.5 mm,h=1 mm: displacement resolution uncertainty is 3.619%, but own-peak-work frame-bracket uncertainty is 25.412%, exceeding 5%. Scoring was withheld. That uncertainty is not a measured material scatter or a 25% curve error.
As additional development diagnostics, a=2/h 1, a=6/h 2 and a=3/h 2 have approximately 1.2%,1.8%,2.1% peak-force differences and−3.2%,−3.1%,−3.5% origin-to-separation work differences. Some global responses are useful for development comparison, but this does not approve every metric or the common profile. Total work was a posthoc diagnostic, not a replacement for the frozen 15% own-peak-work criterion. Moving the peak also moves that criterion's integration start.
A separately versioned numerical-equilibrium policy
The original whole-step static RF-equilibrium test failed the a=4.5 mm fine reference at RMS 7.093% against 5%. That failure is preserved. The left/right time-grid mismatch was zero. RMS was about 0.068% through STATUS-confirmed separation and 15.357% afterward.
Before coefficient identification, a separate plan selected status_load_bearing_equilibrium_v2. The threshold remains 5%, but the static-equilibrium interval is a new definition: through first confirmed complete separation, with normalization from that interval's maximum reaction. Whole-step energy and AE/KE/VD diagnostics remain. Post-separation histories are neither deleted nor smoothed. Dynamic momentum closure of the separated fragments and physical fracture validation have not been established. Material, time and viscosity were not changed for this policy amendment.
Fixed-point stress paths and next work
Eleven cases with stored damage track one fixed integration point per run, selected from the earliest stored positive SDEG. Selected locations differ across shapes/meshes, so eta differences are not asserted to be differences at a common spatial point. The remaining undamaged case is an explicit absence record and stays in the acceptance cohort.
Next steps are initiation/geometry preflight checks, adequate local notch resolution, a separately planned sufficiently fine STATUS output interval, and physical multiaxial observations for initiation/evolution. The formula illustration in the hardening chapter and this synthetic-card campaign are separate evidence sets.
Public evidence and references
Public CSV/JSON excludes private paths, user databases and authentication. The input ZIP preserves keyword/data lines and clarifies comments as synthetic. It is not a claim of a new solve using the public copies. Inputs include failed/unverified conditions and are for review/recomputation, not approved material cards. Large ODBs and internal execution logs are not included.
References: Abaqus damage evolution and characteristic length and Explicit dynamic equilibrium/time integration. Current documentation does not itself verify option support in an older installed solver.
Jaylab · 2026-11-15 · Evidence, assumptions and validation scope are stated in this chapter.