Why can a 10 g pulse produce more than 10 g response?
Apply a 10 g, 11 ms half-sine base pulse to a 100 Hz oscillator with 5% damping. The oscillator starts with zero relative displacement and velocity.
The oscillator stores and releases energy during and after the pulse. Its absolute acceleration therefore differs from base acceleration. SRS repeats this calculation over many natural frequencies and keeps each peak; the peaks do not occur at a single shared time.
Connect the physical quantities
An SRS is built by applying one input time history to many oscillators and recording each response peak. Its frequency axis labels oscillator natural frequency, not the Fourier components of the input. Phase and timing information are lost in the peak operation.
The relationship used in this example
An SRS answers a repeated question: how large would the response of a damped linear oscillator become under this base-acceleration record? The horizontal axis changes the oscillator natural frequency. It does not identify the time when the original shock occurred. Pulse duration matters because each oscillator has its own period, so a single input peak cannot describe the response across all structures.
Work through the example
Base pulse amplitude is 10×9.80665 = 98.0665 m/s².
Integrating the 11 ms half-sine gives velocity change 2AT/π = 0.6867 m/s.
For the stated 100 Hz, 5% damped oscillator, numerical response peaks near 15.914 g; it is not simply the 10 g input peak.
Full example conditions and reference values
Apply a 10 g half-sine base pulse lasting 11 ms, with 1 g = 9.80665 m/s². Its base velocity change is 2×98.0665×0.011/π = 0.6867 m/s. For a 100 Hz oscillator with 5% damping and zero initial relative displacement/velocity, the absolute-acceleration maximax response is approximately 15.914 g. The accompanying plot repeats the solve for different natural frequencies and compares 11 ms with 22 ms at the same 10 g peak. These are synthetic base pulses, not a vehicle crash record.
Compare the numbers before judging the result
| Duration (ms) | Peak base (g) | Base Δv (m/s) |
|---|---|---|
| 11 | 10 | 0.6867418 |
| 22 | 10 | 1.373484 |
This table integrates the input pulse. It does not multiply every SRS response by the same factor.
What the result means for a model
State absolute versus relative response, damping and positive/negative/maximax convention. Continue the solve after the pulse because a response peak can occur during ring-down. Similar SRS curves do not imply identical local stress histories or fatigue damage.
Calculate the maximum over the forced response and subsequent free response, with the same damping and response definition. An SRS envelope discards timing and phase; it is not a unique replacement for a measured crash time history.
Another application: The same peak with twice the pulse duration
A 10 g half-sine lasting 22 ms has twice the base velocity change of the 11 ms pulse: about 1.3734 versus 0.6867 m/s. Their SRS curves need not differ by a constant factor because each oscillator responds to duration relative to its own period.
Further modeling details
1 · Choose the response definition first
Specify absolute acceleration, relative displacement, relative velocity or a pseudo quantity, then specify positive, negative or maximax peaks. The acceleration equation here follows from ax = z̈ + ab. Pseudo-acceleration ωn² max|z| is not generally identical to max|ax| for a damped oscillator. A spectrum without its response type and damping is incomplete.
2 · Keep the ring-down
Start the oscillator at stated initial conditions, integrate through the pulse and continue after the input becomes zero. The largest response may occur during the residual free vibration. A primary spectrum uses the pulse interval; a residual spectrum uses the interval after it. The maximax example retains both. Extend the end time until the recorded peaks no longer change, particularly at low natural frequencies.
3 · Resolve pulse and response time scales
The sample interval must resolve both the input waveform and the highest oscillator frequency of interest. Nyquist frequency alone does not guarantee accurate transient peaks. Reduce the interval, repeat the calculation and compare peak values. Also refine the natural-frequency grid: a time-converged response at a sparse set of frequencies can still miss a spectral maximum between samples.
4 · Compare duration as well as peak
At the same acceleration peak, doubling half-sine duration doubles base velocity change. The effect on each oscillator is not a uniform doubling, because the ratio of pulse duration to natural period changes. For the analytic example, the base is not required to return to its initial velocity: the positive pulse leaves a velocity offset. Avoid silently forcing zero final velocity or deleting baseline content without a physical reason.
5 · Apply to module and pack work
Compare an input spectrum with the relevant modal frequencies and damping as a screening step. The spectrum alone does not reconstruct phases, local stresses or simultaneous bolt loads. A multi-mode response-spectrum calculation needs modal participation and a suitable combination rule; summing all modal peaks at the same instant is generally unjustified. If contact opens or crash deformation is large, retain an appropriate nonlinear time-domain model.
Formula and symbol reference
Open the complete formula reference
| Symbol | Meaning | Unit / convention |
|---|---|---|
| A, T | Half-sine base acceleration peak and duration | m/s²; s |
| z, ax | Relative displacement; absolute response acceleration | m; m/s² |
| Sa | Maximax absolute-acceleration SRS | m/s² or g |
| Q, ζ | Oscillator quality factor convention and damping ratio | dimensionless |
When this example stops applying
Linear viscously damped oscillators with prescribed base acceleration. An SRS is a many-to-one reduction of a time record, not a unique load history and not a direct damage prediction. A positive half-sine is only one pulse shape. Damping and spectrum definitions must match before comparing results.
Check your interpretation
Can you determine the instant of maximum fastener load from an SRS alone?
Show the reasoning
No. The SRS keeps peak magnitudes for separate oscillators and discards their timing and phase relationships. A synchronized time response with the connection model is needed to establish that load history.
Sources and calculation scope
- MathWorks · Shock waveforms and SRS definitions
- NI · Absolute acceleration, primary and residual SRS
- Ansys · Single-point response spectrum analysis
The questions and comparison tables are independently authored teaching examples. Numbers illustrate the stated models; they are not measured cell/pack data or commercial-solver validation.
Comparison calculations (Python)
English / Korean · revised 1 November 2026