Which displacement belongs with the reported force?
Use the stated piecewise-linear 0–80 mm actuator force curve. Integrate its work and compare actuator stroke with a local gap changing from 12 to 3 mm.
Work requires a force and its conjugate displacement. Actuator travel can include deformation throughout the load path, while intrusion is a local geometric change. Mixing the coordinates changes the meaning of a mean-force calculation even if the arithmetic units look correct.
Connect the physical quantities
Actuator stroke is a global test coordinate; intrusion is a change in a locally defined clearance. Work follows the force conjugate to the chosen displacement. Comparing a reaction at one interface with displacement at an unrelated point can produce an invalid energy estimate.
The relationship used in this example
A force–stroke curve summarizes how a structure resists crushing along a chosen loading path. Its area is mechanical work at that load–displacement pair. It does not by itself reveal where deformation occurs or whether a cell is damaged. A useful pack review aligns the curve with deformation states, internal clearances and part-level energy histories.
Work through the example
The first interval contributes (0+80)/2×10 = 400 kN·mm = 400 J.
Summing all trapezoids gives 3400 J over 80 mm.
Mean force is 3400/0.08 = 42.5 kN; mean/peak = 42.5/80 = 0.53125.
Full example conditions and reference values
Use a synthetic curve with (stroke mm, force kN) points (0,0), (10,80), (20,40), (40,40), (60,40), (80,40), connected linearly. Trapezoidal work is 400 + 600 + 800 + 800 + 800 = 3400 J. Over 80 mm, mean force is 42.5 kN, peak force is 80 kN and CFE = 0.53125. With an explicitly chosen 8 kg reference member, SEA = 425 J/kg. Separately, a local clearance falling from 12 to 3 mm means 9 mm intrusion under the stated direction convention. It is not the 80 mm actuator stroke.
Compare the numbers before judging the result
| Stroke interval (mm) | Interval work (J) | Accumulated work (J) |
|---|---|---|
| 0–10 | 400 | 400 |
| 10–20 | 600 | 1000 |
| 20–40 | 800 | 1800 |
| 40–60 | 800 | 2600 |
| 60–80 | 800 | 3400 |
kN×mm equals J; summing the areas gives 3400 J without using the separate local intrusion.
What the result means for a model
Keep intrusion measurement direction and reference points consistent during rotation. Higher energy absorption can coexist with unacceptable cell intrusion. SEA also depends on which mass is included, so state the mass boundary before ranking designs.
Pair reaction force with its work-conjugate displacement. Track local intrusion separately using stated surfaces and direction. Compare frames at matched stroke so a later peak does not appear smaller merely because one run stopped earlier.
Another application: Stroke and cell intrusion are different coordinates
The synthetic curve does 3400 J of work over 80 mm actuator stroke. A local gap changing from 12 to 3 mm means 9 mm intrusion at that location. Dividing 3400 J by 9 mm would combine work and displacement from different coordinates and would not reproduce the curve’s mean force.
Further modeling details
1 · Define force and displacement together
Use the force component and displacement measured at the same work-conjugate interface and along the same direction. A moving rigid platen’s contact resistance paired with its stroke is a common choice; account for actuator/platen inertia if using a measured actuator force. Remote support reactions can differ during a dynamic event. In general external work is the time integral of force dotted with velocity, summed over loaded interfaces.
2 · State the comparison window
Peak force, mean force, CFE and SEA depend on the chosen end stroke, filtering and included hardware. Use the same window and force convention for a design comparison. A filter can lower a sharp peak while leaving work almost unchanged, changing CFE. Retain raw and filtered traces and report filter settings. SEA based on a sacrificial member mass is not directly comparable with SEA normalized by the entire pack.
3 · Track local intrusion in a moving frame
Specify the two surfaces, a measurement direction and a reference frame. Remove rigid-body motion when the intent is local deformation; global displacement alone mixes translation with crushing. A point-pair projected separation, the minimum surface distance and cell-thickness compression are different quantities. In the displayed convention positive intrusion means reduced clearance; a negative result means increased clearance.
4 · Relate curve features to deformation
Inspect synchronized states before the first peak, through folding or contact engagement, at the chosen stroke and after unloading if relevant. A force drop can result from buckling, joint failure, contact loss or numerical deletion. The curve alone cannot distinguish them. For a module or pack, track sidewall intrusion, crossmember load path, module motion and cell-facing contact separately.
5 · Audit work against solver energies
The integral of resistance over stroke is not automatically irreversible absorbed energy. Some work remains recoverable elastic energy, some becomes kinetic energy, and some is dissipated. LS-DYNA energy bookkeeping depends on requested outputs and control settings; its internal energy includes elastic and permanent-deformation contributions. Compare the applicable external work, kinetic, internal, contact and numerical stabilization terms without double counting terms already included in a reported total.
6 · Avoid a universal pass number
A smooth curve or plausible total energy does not establish mesh independence, realistic failure or cell safety. Compare mesh, material-rate response, friction, connections and loading speed against the quantities of interest. For quasi-static explicit crushing, assess inertial sensitivity; for real impact, kinetic energy is part of the physical event. A cell electrical failure criterion requires separate evidence and cannot be inferred from a generic pack intrusion threshold.
Formula and symbol reference
Open the complete formula reference
| Symbol | Meaning | Unit / convention |
|---|---|---|
| F, s | Resistance force and work-conjugate loading-point stroke | kN; mm |
| W, F̄ | Input work over selected stroke; mean resistance | J; kN |
| CFE, SEA | Crush force efficiency; specific work with declared mass | dimensionless; J/kg |
| d0, d(t) | Initial and current clearance along a declared local direction | mm |
When this example stops applying
Synthetic loading-path example. No universal allowable intrusion, CFE or energy ratio is prescribed. Loading work includes recoverable contributions; hysteresis or appropriately defined dissipative output is needed for irreversible absorption. Local failure and electrical safety require validated material and cell models.
Check your interpretation
Design A has higher work under its crush curve. Does that establish better cell protection?
Show the reasoning
No. It may transmit a higher force into the cell stack or consume critical clearance. Compare the same stroke and mass convention, then examine local deformation, transmitted loads and relevant failure criteria. More global work alone is not a cell-safety metric.
Sources and calculation scope
- Ansys LS-DYNA · Energy data and internal energy
- Ansys LS-DYNA · Total energy and external work
- Ansys LS-DYNA · Hourglass response and part-level checks
The questions and comparison tables are independently authored teaching examples. Numbers illustrate the stated models; they are not measured cell/pack data or commercial-solver validation.
Comparison calculations (Python)
English / Korean · revised 1 November 2026