← All theory chapters
Theory / Contact & Connections

Bolt Preload & Joint Separation

Understand how bolt and member stiffness share an external separating load.

Theory · Educational notes · Related tools: Abaqus · LS-DYNA · HyperMesh

Does an external separating load go entirely into the bolt?

Use bolt stiffness 100000 N/mm, member stiffness 300000 N/mm and preload 20000 N. Apply a 10000 N separating load while the joint remains closed.

Part of the load increases bolt tension and the rest relieves member compression. The stiffness ratio determines that split. Once clamp force reaches zero, the assumed closed-joint path changes and the same linear formulas must not be extrapolated.

Connect the physical quantities

Before separation, an external tensile load both increases bolt tension and relieves member compression. The load is divided according to the two elastic stiffnesses. Once the members separate, that load-sharing assumption changes and the same linear equation cannot be extended indefinitely.

The relationship used in this example

C=kbkb+kmC=\frac{k_b}{k_b+k_m}

A preloaded bolt is in tension while the clamped members are in compression. Before separation, an external tensile load both increases bolt tension and reduces member compression. The following two-spring model assumes a concentric axial joint and a specified load introduction.

Work through the example

Step 1

C = 100000/(100000+300000) = 0.25.

Step 2

At P = 10000 N, bolt tension is 20000+2500 = 22500 N; clamp is 20000−7500 = 12500 N.

Step 3

Set clamp to zero: Psep = 20000/0.75 = 26666.7 N.

Full example conditions and reference values

For kb = 100,000 N/mm, km = 300,000 N/mm and Fi = 20,000 N, C = 0.25. At P = 10,000 N, bolt tension is 22,500 N and remaining clamp force is 12,500 N. Ideal separation begins at P = 26,666.7 N. A load cycle from 0 to 10,000 N gives a bolt-force range of 2,500 N before separation; with a 50 mm² stress area, this corresponds to a nominal stress amplitude of 25 MPa.

Bolt tension rises from 20 to 26.67 kN while clamp force falls from 20 to zero as the separating load increases to 26.67 kN.
The two-spring model is plotted only up to predicted separation at 26.67 kN. The remaining clamp force reaches zero; extending this linear relation beyond separation would be invalid.

Compare the numbers before judging the result

Compare the calculated values
P (kN)Bolt force (kN)Clamp force (kN)
02020
1022.512.5
20255
26.6666726.666670

The last row marks ideal separation. The closed-joint equations stop there.

What the result means for a model

For fatigue, use bolt-force range rather than the full external-load range before separation. Flexible flanges, eccentricity and multiple fasteners need a richer load-path model. The ideal formula is a useful baseline, not a prediction of every pack bracket.

Past separation, extending the same straight lines would predict negative clamping, which has no meaning for a compression-only interface. Switch to a model that can open and include prying if the flange bends.

Another application: Why external load is not all added to the bolt

With C = 0.25 and Fi = 20 kN, increasing separating load from 0 to 10 kN raises bolt force by 2.5 kN and reduces clamp force by 7.5 kN. The two changes sum to the external 10 kN. This split applies only while the joint remains closed in the assumed axial model.

Further modeling details

Assembly and service are separate stages

Establish preload, then apply service loading under the intended constraint state. Record whether bolt elongation is held after tightening and how contact settles. A tied interface suppresses the separation this model is intended to examine.

Preload is not torque

A tightening torque is an installation input, not a direct measurement of clamp force. Friction and installation variability can create substantial uncertainty. Use the applicable joint-specific procedure and data rather than treating a nominal torque as exact preload.

EV pack connection

For a pack-to-body mount or module attachment, identify the force path through washers, brackets and local plates. A connector can approximate selected stiffnesses but cannot automatically resolve thread-root stress or local prying.

Review the transition

Plot bolt force and remaining interface compression against applied load. Detect local opening before assuming global separation. If separation occurs, reassess bolt load range and fatigue using a model that permits the changed contact condition.

Formula and symbol reference

Open the complete formula reference
C=kbkb+kmC=\frac{k_b}{k_b+k_m}
Fb=Fi+CPF_b=F_i+CP
Fclamp=Fi−(1−C)PF_{\mathrm{clamp}}=F_i-(1-C)P
Psep=Fi1−CP_{\mathrm{sep}}=\frac{F_i}{1-C}
SymbolMeaningUnit / convention
kb, kmBolt tensile stiffness; clamped-member stiffnessN/mm
FiInitial preload magnitudeN
PExternal axial separating loadN
Fb, FclampBolt tension; remaining compression magnitudeN
CLoad fraction for this idealized load introductiondimensionless

When this example stops applying

These equations apply only while the ideal joint remains clamped. Prying, eccentric load introduction, bending, gasket behavior and multiple fasteners change load sharing. Bolt strength, thread stripping, bearing, slip and fatigue require separate checks. Preload scatter, embedding and temperature changes are not represented by the fixed Fi example.

Check your interpretation

Does a 10 kN separating load always add 10 kN to bolt tension?

Show the reasoning

No. Before separation, the simple model assigns only CP to the bolt; after separation the model and load path change.

Sources and calculation scope

The questions and comparison tables are independently authored teaching examples. Numbers illustrate the stated models; they are not measured cell/pack data or commercial-solver validation.

Comparison calculations (Python)

English / Korean · revised 1 November 2026