  "source": "https://doi.org/10.1016/j.est.2021.102517",
  "figure": "6(b)",
  "pdf_page": 10,
  "source_crop": {
    "pdf_box": [
      295,
      48,
      550,
      248
    ],
    "scale": 4,
    "zero_mm_px": 229,
    "eight_mm_px": 962,
    "zero_MPa_px": 683,
    "one_point_five_MPa_px": 225
  },
  "method": "Manually read experimental colored marker centers. Black module stiffness line and purple bulging arrow excluded. Rounded pressure group labels are approximate, not exact commanded steps.",
  "caution": "Reading allowances are analyst estimates for digitization only, not metrological accuracy or experimental confidence intervals.",
  "rows": [
    {
      "approx_pressure_MPa": 0.41,
      "point": 1,
      "location": "corner",
      "displacement_mm": 0.73,
      "marker_x_px": 296,
      "marker_y_px": 558,
      "pressure_from_marker_MPa": 0.409,
      "data_kind": "manual original-figure digitization; hydraulic surrogate test",
      "SOC": "not applicable to hydraulic replacement test",
      "temperature_C": "not specified for spreading test",
      "displacement_reading_allowance_mm": 0.1,
      "pressure_reading_allowance_MPa": 0.03
    },
    {
      "approx_pressure_MPa": 0.41,
      "point": 2,
      "location": "corner",
      "displacement_mm": 0.7,
      "marker_x_px": 293,
      "marker_y_px": 559,
      "pressure_from_marker_MPa": 0.406,
      "data_kind": "manual original-figure digitization; hydraulic surrogate test",
      "SOC": "not applicable to hydraulic replacement test",
      "temperature_C": "not specified for spreading test",
      "displacement_reading_allowance_mm": 0.1,
      "pressure_reading_allowance_MPa": 0.03
    },
    {
      "approx_pressure_MPa": 0.41,
      "point": 3,
      "location": "edge center",
      "displacement_mm": 2.28,
      "marker_x_px": 438,
      "marker_y_px": 559,
      "pressure_from_marker_MPa": 0.406,
      "data_kind": "manual original-figure digitization; hydraulic surrogate test",
      "SOC": "not applicable to hydraulic replacement test",
      "temperature_C": "not specified for spreading test",
      "displacement_reading_allowance_mm": 0.1,
      "pressure_reading_allowance_MPa": 0.03
    },
    {
      "approx_pressure_MPa": 0.82,
      "point": 1,
      "location": "corner",
      "displacement_mm": 0.87,
      "marker_x_px": 309,
      "marker_y_px": 433,
      "pressure_from_marker_MPa": 0.819,
      "data_kind": "manual original-figure digitization; hydraulic surrogate test",
      "SOC": "not applicable to hydraulic replacement test",
      "temperature_C": "not specified for spreading test",
      "displacement_reading_allowance_mm": 0.1,
      "pressure_reading_allowance_MPa": 0.03
    },
    {
      "approx_pressure_MPa": 0.82,
      "point": 2,
      "location": "corner",
      "displacement_mm": 1.27,
      "marker_x_px": 345,
      "marker_y_px": 432,
      "pressure_from_marker_MPa": 0.822,
      "data_kind": "manual original-figure digitization; hydraulic surrogate test",
      "SOC": "not applicable to hydraulic replacement test",
      "temperature_C": "not specified for spreading test",
      "displacement_reading_allowance_mm": 0.1,
      "pressure_reading_allowance_MPa": 0.03
    },
    {
      "approx_pressure_MPa": 0.82,
      "point": 3,
      "location": "edge center",
      "displacement_mm": 3.29,
      "marker_x_px": 530,
      "marker_y_px": 433,
      "pressure_from_marker_MPa": 0.819,
      "data_kind": "manual original-figure digitization; hydraulic surrogate test",
      "SOC": "not applicable to hydraulic replacement test",
      "temperature_C": "not specified for spreading test",
      "displacement_reading_allowance_mm": 0.1,
      "pressure_reading_allowance_MPa": 0.03
    },
    {
      "approx_pressure_MPa": 1.23,
      "point": 1,
      "location": "corner",
      "displacement_mm": 2.31,
      "marker_x_px": 441,
      "marker_y_px": 307,
      "pressure_from_marker_MPa": 1.231,
      "data_kind": "manual original-figure digitization; hydraulic surrogate test",
      "SOC": "not applicable to hydraulic replacement test",
      "temperature_C": "not specified for spreading test",
      "displacement_reading_allowance_mm": 0.1,
      "pressure_reading_allowance_MPa": 0.03
    },
    {
      "approx_pressure_MPa": 1.23,
      "point": 2,
      "location": "corner",
      "displacement_mm": 1.9,
      "marker_x_px": 403,
      "marker_y_px": 307,
      "pressure_from_marker_MPa": 1.231,
      "data_kind": "manual original-figure digitization; hydraulic surrogate test",
      "SOC": "not applicable to hydraulic replacement test",
      "temperature_C": "not specified for spreading test",
      "displacement_reading_allowance_mm": 0.1,
      "pressure_reading_allowance_MPa": 0.03
    },
    {
      "approx_pressure_MPa": 1.23,
      "point": 3,
      "location": "edge center",
      "displacement_mm": 4.75,
      "marker_x_px": 664,
      "marker_y_px": 307,
      "pressure_from_marker_MPa": 1.231,
      "data_kind": "manual original-figure digitization; hydraulic surrogate test",
      "SOC": "not applicable to hydraulic replacement test",
      "temperature_C": "not specified for spreading test",
      "displacement_reading_allowance_mm": 0.1,
      "pressure_reading_allowance_MPa": 0.03
    },
    {
      "approx_pressure_MPa": 1.64,
      "point": 1,
      "location": "corner",
      "displacement_mm": 3.83,
      "marker_x_px": 580,
      "marker_y_px": 181,
      "pressure_from_marker_MPa": 1.644,
      "data_kind": "manual original-figure digitization; hydraulic surrogate test",
      "SOC": "not applicable to hydraulic replacement test",
      "temperature_C": "not specified for spreading test",
      "displacement_reading_allowance_mm": 0.1,
      "pressure_reading_allowance_MPa": 0.03
    },
    {
      "approx_pressure_MPa": 1.64,
      "point": 2,
      "location": "corner",
      "displacement_mm": 3.71,
      "marker_x_px": 569,
      "marker_y_px": 182,
      "pressure_from_marker_MPa": 1.641,
      "data_kind": "manual original-figure digitization; hydraulic surrogate test",
      "SOC": "not applicable to hydraulic replacement test",
      "temperature_C": "not specified for spreading test",
      "displacement_reading_allowance_mm": 0.1,
      "pressure_reading_allowance_MPa": 0.03
    },
    {
      "approx_pressure_MPa": 1.64,
      "point": 3,
      "location": "edge center",
      "displacement_mm": 7.07,
      "marker_x_px": 877,
      "marker_y_px": 182,
      "pressure_from_marker_MPa": 1.641,
      "data_kind": "manual original-figure digitization; hydraulic surrogate test",
      "SOC": "not applicable to hydraulic replacement test",
      "temperature_C": "not specified for spreading test",
      "displacement_reading_allowance_mm": 0.1,
      "pressure_reading_allowance_MPa": 0.03
    }
  ]
}