  "source": "https://fastestproject.eu/wp-content/uploads/2026/06/D3.4-Physical-testing-report-for-model-validation-and-characterization_compressed.pdf",
  "scope": "Module terminal weld representative simplified structural model, not complete module or pack validation",
  "source_PDFs": [
    {
      "file": "D3.4.pdf",
      "pages": 32,
      "url": "https://fastestproject.eu/wp-content/uploads/2026/06/D3.4-Physical-testing-report-for-model-validation-and-characterization_compressed.pdf",
      "sha256": "f7291da29da67d022973ee2638ce760063d38d8c4897d7228499854a5916dc4b"
    },
    {
      "file": "D3.2.pdf",
      "pages": 32,
      "url": "https://fastestproject.eu/wp-content/uploads/2026/06/D3.2-Reduced-order-model-development-and-validation_compressed.pdf",
      "sha256": "44e7478c29be05569de085fe36996050513c5ad9e178e54c0abd027086a871ad"
    }
  ],
  "table4_recalculation": {
    "T1": {
      "n": 10,
      "mean_min": 20.1,
      "sample_std_min": 3.478505426185217
    },
    "T2": {
      "n": 4,
      "mean_min": 37.5,
      "sample_std_min": 2.8867513459481287
    }
  },
  "reported_damping_percent": {
    "weld1": [
      2.6,
      0.731
    ],
    "weld2": [
      2.37,
      0.734
    ],
    "mean": [
      2.485,
      0.733
    ]
  },
  "frequency_versions": {
    "body_FE_Hz": [
      13.75,
      46.66
    ],
    "table2_measured_mean_Hz": [
      13.5,
      44.5
    ],
    "table3_FE_Hz": [
      13.5,
      43
    ],
    "table3_test_Hz": [
      13.5,
      46
    ],
    "table3_reported_error_percent": [
      0,
      6.9
    ]
  },
  "Table5_conditional_life_difference": [
    {
      "numerical_min": 20.1,
      "experimental_min": 18.3,
      "signed_difference_percent": 9.836065573770494,
      "meaning": "Conditional arithmetic from Table5 only; experimental cohort differs from Table4; not a resolved validation error"
    },
    {
      "numerical_min": 37.5,
      "experimental_min": 51.3,
      "signed_difference_percent": -26.900584795321635,
      "meaning": "Conditional arithmetic from Table5 only; experimental cohort differs from Table4; not a resolved validation error"
    }
  ],
  "raw_data_acquired": false,
  "digitized_curves": 0,
  "ISMA_full_paper_acquired": false,
  "acquisition_block": "ISMA2026 Contribution263 and abstract return401; Bologna2026 paper embargo until2028-02-13",
  "cross_reference_note": "D3.4 p14 says See D3.2 for structural workflow; acquired public D3.2 mainly electrochemical/thermal ROM and does not resolve structural contact/solver settings."
}