  "source": "https://fenix.tecnico.ulisboa.pt/downloadFile/844820067128283/ExtendedAbstract_Thesis_87233_LuisFigueiredo_Fenix.pdf",
  "sourceType": "10-page extended abstract; complete dissertation not acquired",
  "frequencyAudit": [
    {
      "mode": "first bending",
      "FE_Hz": 45.34,
      "test_Hz": 50,
      "published_absolute_error_Hz": 4.66,
      "published_relative_percent": 9.32,
      "recalculated_signed_error_Hz": -4.659999999999997,
      "recalculated_absolute_error_Hz": 4.659999999999997,
      "recalculated_relative_percent": 9.319999999999993,
      "data_origin": "Published Table2 numeric transcription, not raw modal data or digitization"
    },
    {
      "mode": "first torsion",
      "FE_Hz": 61.76,
      "test_Hz": 60,
      "published_absolute_error_Hz": 5.95,
      "published_relative_percent": 2.93,
      "recalculated_signed_error_Hz": 1.759999999999998,
      "recalculated_absolute_error_Hz": 1.759999999999998,
      "recalculated_relative_percent": 2.93333333333333,
      "data_origin": "Published Table2 numeric transcription, not raw modal data or digitization"
    }
  ],
  "shakerSampleCount": 8001,
  "shakerDuration_s": 10,
  "reportedVehicleTimeStep_s": 0.025,
  "nyquist_Hz": 20,
  "rawAccelerationAvailable": false,
  "rawFEModelAvailable": false,
  "digitizedCurves": 0,
  "testPhotoAcquired": false,
  "packPhotoAcquired": true,
  "limits": [
    "Test PSD blurred for customer confidentiality; do not digitize gray region as a curve",
    "MAC>80% refers to members FE vs beam FE, not pack test vs FE",
    "4-80x refers to normalized acceleration pseudo-damage, not validated fatigue life"
  ]
}