  "scope": "ZIP CRC, inventory and timestamp bounds only; not synchronized or calibrated",
  "md5": "b9ed863766e30afbd0e309951c855d08",
  "md5_matches_repository": true,
  "crc_pass": true,
  "cell_format": "prismatic; publisher methods section 3.1",
  "row_counts": {
    "electrical": 1091337,
    "thickness_sensors": 234021
  },
  "files": [
    {
      "file": "2024-06-12_15-15-07-338830_2773.log",
      "cell": "01",
      "type": "electrical",
      "rows": 253861,
      "start": "2024-06-12T15:15:07.460346",
      "end": "2024-06-15T23:36:03.030526",
      "time_parse_failures": 0,
      "duplicate_timestamps": 0,
      "backward_steps": 0
    },
    {
      "file": "SP_NEMO NCM75AH_NEMO NCM75AH_12_06_2024_15_31_02_logfile.txt",
      "cell": "01",
      "type": "thickness_sensors",
      "rows": 17486,
      "start": "2024-06-12T15:31:37",
      "end": "2024-06-13T15:51:33",
      "time_parse_failures": 0,
      "duplicate_timestamps": 0,
      "backward_steps": 0,
      "overlaps_electrical_time_range": true,
      "time_join_status": "ELIGIBLE_FOR_PROTOCOL_REVIEW"
    },
    {
      "file": "SP_NEMO NCM75AH_NEMO NCM75AH_13_06_2024_15_51_49_logfile.txt",
      "cell": "01",
      "type": "thickness_sensors",
      "rows": 13217,
      "start": "2024-06-13T15:51:49",
      "end": "2024-06-14T10:15:09",
      "time_parse_failures": 0,
      "duplicate_timestamps": 0,
      "backward_steps": 0,
      "overlaps_electrical_time_range": true,
      "time_join_status": "ELIGIBLE_FOR_PROTOCOL_REVIEW"
    },
    {
      "file": "SP_NEMO NCM75AH_NEMO NCM75AH_14_06_2024_10_15_26_logfile.txt",
      "cell": "01",
      "type": "thickness_sensors",
      "rows": 16113,
      "start": "2024-06-14T10:15:26",
      "end": "2024-06-15T08:40:35",
      "time_parse_failures": 0,
      "duplicate_timestamps": 0,
      "backward_steps": 0,
      "overlaps_electrical_time_range": true,
      "time_join_status": "ELIGIBLE_FOR_PROTOCOL_REVIEW"
    },
    {
      "file": "2024-10-28_10-15-09-323202_3604.log",
      "cell": "02",
      "type": "electrical",
      "rows": 207383,
      "start": "2024-10-28T10:15:09.439927",
      "end": "2024-10-31T03:44:26.507231",
      "time_parse_failures": 0,
      "duplicate_timestamps": 0,
      "backward_steps": 0
    },
    {
      "file": "SP_NEMO NCM75AH_NEMO NCM75AH_28_10_2024_10_30_30_logfile.txt",
      "cell": "02",
      "type": "thickness_sensors",
      "rows": 17520,
      "start": "2024-10-28T10:30:30",
      "end": "2024-10-29T10:53:15",
      "time_parse_failures": 0,
      "duplicate_timestamps": 0,
      "backward_steps": 0,
      "overlaps_electrical_time_range": true,
      "time_join_status": "ELIGIBLE_FOR_PROTOCOL_REVIEW"
    },
    {
      "file": "SP_NEMO NCM75AH_NEMO NCM75AH_29_10_2024_10_53_43_logfile.txt",
      "cell": "02",
      "type": "thickness_sensors",
      "rows": 13211,
      "start": "2024-10-29T10:53:43",
      "end": "2024-10-30T05:16:50",
      "time_parse_failures": 0,
      "duplicate_timestamps": 0,
      "backward_steps": 0,
      "overlaps_electrical_time_range": true,
      "time_join_status": "ELIGIBLE_FOR_PROTOCOL_REVIEW"
    },
    {
      "file": "SP_NEMO NCM75AH_NEMO NCM75AH_30_10_2024_05_17_18_logfile.txt",
      "cell": "02",
      "type": "thickness_sensors",
      "rows": 16124,
      "start": "2024-10-30T05:17:18",
      "end": "2024-10-31T03:43:48",
      "time_parse_failures": 0,
      "duplicate_timestamps": 0,
      "backward_steps": 0,
      "overlaps_electrical_time_range": true,
      "time_join_status": "ELIGIBLE_FOR_PROTOCOL_REVIEW"
    },
    {
      "file": "2025-09-04_10-05-34-441487_4405.log",
      "cell": "03",
      "type": "electrical",
      "rows": 210541,
      "start": "2025-09-04T10:05:34.557182",
      "end": "2025-09-07T03:34:30.187882",
      "time_parse_failures": 0,
      "duplicate_timestamps": 0,
      "backward_steps": 0
    },
    {
      "file": "SP_NEMO NCM75AH_NEMO NCM75AH_04_09_2025_10_16_47_logfile.txt",
      "cell": "03",
      "type": "thickness_sensors",
      "rows": 17525,
      "start": "2025-09-04T10:16:47",
      "end": "2025-09-05T10:39:43",
      "time_parse_failures": 0,
      "duplicate_timestamps": 0,
      "backward_steps": 0,
      "overlaps_electrical_time_range": true,
      "time_join_status": "ELIGIBLE_FOR_PROTOCOL_REVIEW"
    },
    {
      "file": "SP_NEMO NCM75AH_NEMO NCM75AH_09_09_2025_12_50_53_logfile.txt",
      "cell": "03",
      "type": "thickness_sensors",
      "rows": 13215,
      "start": "2025-09-09T12:50:53",
      "end": "2025-09-10T07:14:00",
      "time_parse_failures": 0,
      "duplicate_timestamps": 0,
      "backward_steps": 0,
      "overlaps_electrical_time_range": false,
      "time_join_status": "HOLD_NO_TIME_OVERLAP"
    },
    {
      "file": "SP_NEMO NCM75AH_NEMO NCM75AH_10_09_2025_08_17_34_logfile.txt",
      "cell": "03",
      "type": "thickness_sensors",
      "rows": 16133,
      "start": "2025-09-10T08:17:34",
      "end": "2025-09-11T06:44:18",
      "time_parse_failures": 0,
      "duplicate_timestamps": 0,
      "backward_steps": 0,
      "overlaps_electrical_time_range": false,
      "time_join_status": "HOLD_NO_TIME_OVERLAP"
    },
    {
      "file": "2024-11-07_09-22-48-690630_3667.log",
      "cell": "04",
      "type": "electrical",
      "rows": 209558,
      "start": "2024-11-07T09:22:48.808999",
      "end": "2024-11-10T02:37:43.512045",
      "time_parse_failures": 0,
      "duplicate_timestamps": 0,
      "backward_steps": 0
    },
    {
      "file": "SP_NEMO NCM75AH_NEMO NCM75AH_07_11_2024_09_39_13_logfile.txt",
      "cell": "04",
      "type": "thickness_sensors",
      "rows": 17358,
      "start": "2024-11-07T09:39:13",
      "end": "2024-11-08T09:48:15",
      "time_parse_failures": 0,
      "duplicate_timestamps": 0,
      "backward_steps": 0,
      "overlaps_electrical_time_range": true,
      "time_join_status": "ELIGIBLE_FOR_PROTOCOL_REVIEW"
    },
    {
      "file": "SP_NEMO NCM75AH_NEMO NCM75AH_08_11_2024_09_48_43_logfile.txt",
      "cell": "04",
      "type": "thickness_sensors",
      "rows": 13188,
      "start": "2024-11-08T09:48:43",
      "end": "2024-11-09T04:09:35",
      "time_parse_failures": 0,
      "duplicate_timestamps": 0,
      "backward_steps": 0,
      "overlaps_electrical_time_range": true,
      "time_join_status": "ELIGIBLE_FOR_PROTOCOL_REVIEW"
    },
    {
      "file": "SP_NEMO NCM75AH_NEMO NCM75AH_09_11_2024_04_10_03_logfile.txt",
      "cell": "04",
      "type": "thickness_sensors",
      "rows": 16137,
      "start": "2024-11-09T04:10:03",
      "end": "2024-11-10T02:37:05",
      "time_parse_failures": 0,
      "duplicate_timestamps": 0,
      "backward_steps": 0,
      "overlaps_electrical_time_range": true,
      "time_join_status": "ELIGIBLE_FOR_PROTOCOL_REVIEW"
    },
    {
      "file": "2024-11-14_08-52-42-654239_3692.log",
      "cell": "05",
      "type": "electrical",
      "rows": 209994,
      "start": "2024-11-14T08:52:42.764567",
      "end": "2024-11-17T02:16:44.679165",
      "time_parse_failures": 0,
      "duplicate_timestamps": 0,
      "backward_steps": 0
    },
    {
      "file": "SP_NEMO NCM75AH_NEMO NCM75AH_14_11_2024_09_09_08_logfile.txt",
      "cell": "05",
      "type": "thickness_sensors",
      "rows": 17395,
      "start": "2024-11-14T09:09:08",
      "end": "2024-11-15T09:21:15",
      "time_parse_failures": 0,
      "duplicate_timestamps": 0,
      "backward_steps": 0,
      "overlaps_electrical_time_range": true,
      "time_join_status": "ELIGIBLE_FOR_PROTOCOL_REVIEW"
    },
    {
      "file": "SP_NEMO NCM75AH_NEMO NCM75AH_15_11_2024_09_21_43_logfile.txt",
      "cell": "05",
      "type": "thickness_sensors",
      "rows": 13224,
      "start": "2024-11-15T09:21:43",
      "end": "2024-11-16T03:45:29",
      "time_parse_failures": 0,
      "duplicate_timestamps": 0,
      "backward_steps": 0,
      "overlaps_electrical_time_range": true,
      "time_join_status": "ELIGIBLE_FOR_PROTOCOL_REVIEW"
    },
    {
      "file": "SP_NEMO NCM75AH_NEMO NCM75AH_16_11_2024_03_45_57_logfile.txt",
      "cell": "05",
      "type": "thickness_sensors",
      "rows": 16175,
      "start": "2024-11-16T03:45:57",
      "end": "2024-11-17T02:16:06",
      "time_parse_failures": 0,
      "duplicate_timestamps": 0,
      "backward_steps": 0,
      "overlaps_electrical_time_range": true,
      "time_join_status": "ELIGIBLE_FOR_PROTOCOL_REVIEW"
    }
  ],
  "inventory": [
    {
      "name": "Experimental data for battery compression force prediction under mechanical constraints/Fresh cell 01/2024-06-12_15-15-07-338830_2773.log",
      "bytes": 12684049,
      "sha256": "a72443b451bb5a6f49700f0dc4424261c3f7bb3464cbbd92e7be0492f9bd805e"
    },
    {
      "name": "Experimental data for battery compression force prediction under mechanical constraints/Fresh cell 01/SP_NEMO NCM75AH_NEMO NCM75AH_12_06_2024_15_31_02_logfile.txt",
      "bytes": 1766656,
      "sha256": "238576db0eeeb4b9079deb12b0b345723d3a65541ba6398a4e7b03ec9fe05e47"
    },
    {
      "name": "Experimental data for battery compression force prediction under mechanical constraints/Fresh cell 01/SP_NEMO NCM75AH_NEMO NCM75AH_13_06_2024_15_51_49_logfile.txt",
      "bytes": 1335488,
      "sha256": "e834824adcae3401a6473660cb1e0bf72d3a3795220dde87659ee321f79d8915"
    },
    {
      "name": "Experimental data for battery compression force prediction under mechanical constraints/Fresh cell 01/SP_NEMO NCM75AH_NEMO NCM75AH_14_06_2024_10_15_26_logfile.txt",
      "bytes": 1627984,
      "sha256": "1df6dcb7315dfdcbe230b5229115f0fed9ad54225922a9a4f3cd728b44b1f5ac"
    },
    {
      "name": "Experimental data for battery compression force prediction under mechanical constraints/Fresh cell 02/2024-10-28_10-15-09-323202_3604.log",
      "bytes": 10378476,
      "sha256": "1d7aeedb87cb7bec6844f823738f778fe8ff1a53b956568de8d3bfca9007a906"
    },
    {
      "name": "Experimental data for battery compression force prediction under mechanical constraints/Fresh cell 02/SP_NEMO NCM75AH_NEMO NCM75AH_28_10_2024_10_30_30_logfile.txt",
      "bytes": 1770091,
      "sha256": "046aaa5478ecba6111e37f98caa5e25b2fc0e490a62be9c779049cda9b4bfc14"
    },
    {
      "name": "Experimental data for battery compression force prediction under mechanical constraints/Fresh cell 02/SP_NEMO NCM75AH_NEMO NCM75AH_29_10_2024_10_53_43_logfile.txt",
      "bytes": 1334881,
      "sha256": "bee361973ec676676ddcb73a30802e547ef5853413ca0f58953c57d73cf56f1c"
    },
    {
      "name": "Experimental data for battery compression force prediction under mechanical constraints/Fresh cell 02/SP_NEMO NCM75AH_NEMO NCM75AH_30_10_2024_05_17_18_logfile.txt",
      "bytes": 1629095,
      "sha256": "429fe747c3f5fd656fe44df6b175e2178cc5b940cd3e0490c47d5fecba511a62"
    },
    {
      "name": "Experimental data for battery compression force prediction under mechanical constraints/Fresh cell 03/2025-09-04_10-05-34-441487_4405.log",
      "bytes": 10537709,
      "sha256": "1f08d523e94072d20ca474012f9d5d5900b34d79e293684b2ef6c4af44289cee"
    },
    {
      "name": "Experimental data for battery compression force prediction under mechanical constraints/Fresh cell 03/SP_NEMO NCM75AH_NEMO NCM75AH_04_09_2025_10_16_47_logfile.txt",
      "bytes": 1770596,
      "sha256": "239d7faeed23f75ff65c4da38e3ce0b7ce9372f4dc2f1c9cb24d8c085cab94e5"
    },
    {
      "name": "Experimental data for battery compression force prediction under mechanical constraints/Fresh cell 03/SP_NEMO NCM75AH_NEMO NCM75AH_09_09_2025_12_50_53_logfile.txt",
      "bytes": 1335286,
      "sha256": "65641a7790c77ea7559b2e5ac1e656b2ceebc867640a650e366fe9515a726222"
    },
    {
      "name": "Experimental data for battery compression force prediction under mechanical constraints/Fresh cell 03/SP_NEMO NCM75AH_NEMO NCM75AH_10_09_2025_08_17_34_logfile.txt",
      "bytes": 1630004,
      "sha256": "8fb144f25d18e6f4b82e293cd7f70a1a63a276318243838f45b11040a8fb0fcf"
    },
    {
      "name": "Experimental data for battery compression force prediction under mechanical constraints/Fresh cell 04/2024-11-07_09-22-48-690630_3667.log",
      "bytes": 10482023,
      "sha256": "a732f97eca1d60d9a1b2c840e218f533e6cd6add3aeb6fe38bfe1eee5a9d19a0"
    },
    {
      "name": "Experimental data for battery compression force prediction under mechanical constraints/Fresh cell 04/SP_NEMO NCM75AH_NEMO NCM75AH_07_11_2024_09_39_13_logfile.txt",
      "bytes": 1753729,
      "sha256": "1c399bcde05248d28698db40d4aec5e576c68a6dfe15418e673948485120cf20"
    },
    {
      "name": "Experimental data for battery compression force prediction under mechanical constraints/Fresh cell 04/SP_NEMO NCM75AH_NEMO NCM75AH_08_11_2024_09_48_43_logfile.txt",
      "bytes": 1332559,
      "sha256": "b36d7e7441de1bea3592a7a6447382cc3957d410da68aa08639b84662c6fd181"
    },
    {
      "name": "Experimental data for battery compression force prediction under mechanical constraints/Fresh cell 04/SP_NEMO NCM75AH_NEMO NCM75AH_09_11_2024_04_10_03_logfile.txt",
      "bytes": 1630408,
      "sha256": "e244878051cec9fa2bf1deb8940b26282b27f02ab9410a66e6a710fe1e9e3723"
    },
    {
      "name": "Experimental data for battery compression force prediction under mechanical constraints/Fresh cell 05/2024-11-14_08-52-42-654239_3692.log",
      "bytes": 10499015,
      "sha256": "a5fd1ff1b324ad8c0931142bcb6e2eab8336865a806bf9d56df47575d14a3cc0"
    },
    {
      "name": "Experimental data for battery compression force prediction under mechanical constraints/Fresh cell 05/SP_NEMO NCM75AH_NEMO NCM75AH_14_11_2024_09_09_08_logfile.txt",
      "bytes": 1757466,
      "sha256": "c83c9b36539398d5d7bc38f20034be8a9761829570c32af7407c1a8912bcd20e"
    },
    {
      "name": "Experimental data for battery compression force prediction under mechanical constraints/Fresh cell 05/SP_NEMO NCM75AH_NEMO NCM75AH_15_11_2024_09_21_43_logfile.txt",
      "bytes": 1336194,
      "sha256": "90c7c7344f19bd571fffcb5cd729beb33dd0ac4dde83f726174f2ec297c32ba5"
    },
    {
      "name": "Experimental data for battery compression force prediction under mechanical constraints/Fresh cell 05/SP_NEMO NCM75AH_NEMO NCM75AH_16_11_2024_03_45_57_logfile.txt",
      "bytes": 1634245,
      "sha256": "24c5a82d3aadab73b62524b6e2a25a7cabf9d6753d5ddd836ea6631ab2de2694"
    },
    {
      "name": "Experimental data for battery compression force prediction under mechanical constraints/ReadME.txt",
      "bytes": 292,
      "sha256": "f12df80c6e3839d87c7fd797752009d749b97868b945d83794baf3d673cd49c8"
    }
  ],
  "limitations": [
    "Timezone and sensor conversion unresolved",
    "Preload is not measured force history",
    "F03 two SP files have no electrical time overlap; no date correction applied",
    "No physical calibration, train/holdout scoring, or material approval"
  ]
}