  "status": "proposal, not implemented or physically calibrated",
  "version": "0.1",
  "reference_state": [
    "cell_id",
    "chemistry",
    "form_factor",
    "material_axis",
    "reference_SOC_0_to_1",
    "reference_temperature_K",
    "thickness_m",
    "reference_preload_N",
    "conditioning_history"
  ],
  "material_groups": {
    "free_expansion": "directional stretch vs SOC, T, charge/discharge branch; thermal contribution explicitly separated",
    "mechanical": "fixed SOC/T compression unloading shear; anisotropy and transverse response",
    "relaxation": "fixed SOC/T hold/recovery, characteristic times and pressure dependence",
    "aging": "stress-free residual thickness distinct from mechanical set; gas contribution only if separately identifiable"
  },
  "fixture": [
    "boundary_type_fixed_gap_constant_force_spring_feedback",
    "stiffness_N_per_m",
    "force_drift",
    "temperature_drift",
    "pad_id_and_conditioning",
    "sensor_position",
    "contact_area_m2",
    "time_sync_method"
  ],
  "training_data_provenance": [
    "source_DOI",
    "source_file_hash",
    "material_card_version",
    "solver_version",
    "element_mesh_contact",
    "calibration_or_holdout",
    "measured_digitized_or_synthetic",
    "numerical_gate_status",
    "physical_gate_status"
  ],
  "sign_conventions": "Decide explicitly: UMAT Cauchy stress tension-positive; reported compression force may be positive; map once at data boundary.",
  "gates": [
    "source integrity",
    "material point/element numerical checks",
    "fixture compensation",
    "independent cell holdout",
    "independent assembly holdout"
  ],
  "acceptance_thresholds": "To be fixed before scoring from intended accuracy and measurement repeatability; not assigned from literature fitting accuracy."
}