DPC native baseline v0.1 — 2026-11-17

Two deliberately separate evidence streams
1. Zhu et al. 2019 Fig.5 raster digitization, DOI 10.1016/j.ijplas.2019.06.011.
   Graphite 69 sampled points and NMC 60 sampled points; published curve values, NOT raw tests.
   Red/blue color selection, verified axis pixels, excluded text labels, median ordinate per column.
   Preserve small decreases and do not extrapolate to zero or beyond plotted support.
   A +/-2 pixel axis-registration assumption gives about 0.000823 strain and 0.326 MPa;
   it is not a complete digitization or experimental uncertainty bound.
   Source image and original PDF are in the NAS private research archive.

2. Abaqus/Standard 6.14-5 native DPC NUMERICAL fixtures.
   ALL material constants are synthetic: E=1000 MPa, nu=.25, d=5 MPa, beta=30 deg,
   R=.5, alpha=0, K ratio=1, pb=10+200*kappa MPa, kappa positive compressive
   inelastic volume strain, initial position zero. No source curve is used in these decks.
   N-mm-MPa units, a 1 mm C3D8 cube with 8 integration points, NLGEOM=NO.
   Six cases: multiaxial elastic, hydrostatic load-unload-reload, confined compression
   and shear, with half maximum increments for the latter two.
   These checks do NOT reproduce Zhu's cell indentation experiments or approve a material card.

Conventions that must be preserved
- Abaqus CAP HARDENING expects pb, not pa; pb=pa*(1+R*tan(beta))+R*d.
- Positive hardening abscissa is the absolute inelastic volume strain.
- PEQC4 is signed volumetric inelastic strain; trace(PE) is checked separately.
- PEEQ is cap position pb for this model, NOT equivalent plastic strain.
- In the tested 6.14 ODB, PEQC1, PEQC2, PEQC3, PEQC4 are separate scalar fields.
  The extractor keeps each field and creates a checked combined PEQC representation.
- For the current K=1 fixture the deviatoric invariant t equals von Mises q.

Reproduce the numerical cases
python3 generate_cases.py
Copy cases/*.inp, extract_odb.py, run_native.cmd into a NEW Windows job directory.
Run run_native.cmd with an installed/licensed Abaqus 6.14 environment.
No Intel Fortran or UMAT is used by these native cases.
Copy the .odb.json, .sta, dc_*.dat and dc_*_console.txt files back to one directory.
python3 score_results.py <run_directory> <results_directory>
ACCEPTANCE.json was fixed before the initial solver run; no tolerances were relaxed.
Elastic and hydrostatic stresses have independent analytical references.
The hydrostatic plastic work has an independent integral reference.
Confined/shear checks cover yield admissibility, hardening, signed strain, elastic energy,
energy balance, nonnegative plastic work and increment refinement; no independent general
multiaxial return-mapping oracle is claimed.

Reproduce digitization
python3 digitize_figure5.py <original embedded page8_image0.jpeg> digitized
python3 map_published_pressure.py
The mapped CSV changes ONLY the pressure ordinate. Its strain axis remains unresolved.
Do not paste the mapped CSV directly into CAP HARDENING.

Unresolved paper-reproduction inputs
Fig.5 strain measure (total vs plastic, engineering vs logarithmic), elastic subtraction,
initial cap/precompaction reference, source-specific coating elasticity and transition alpha.
The paper's coating parameters must not be relabelled as whole-pouch properties.
The next physical validation level requires prescribed geometry, contact/friction,
layer properties and independent loading-case holdouts.

Failure provenance
Run 01 failed input processing because initial node-set BCs were modified using individual
node labels. Run 02 explicitly replaces all prescribed BCs with OP=NEW.
Material constants and acceptance tolerances stayed unchanged.
An exporter-only correction combined the separate PEQC1-4 fields after the run;
the ODBs were opened read-only, and the solver cases were not rerun for that correction.
Both input failure and final raw solver evidence are retained in the NAS archive.

Publication rebuild order
The parent library v1 generator may be run first. Run this study's build_report.py after it
to add the native-fixture status and digitization links without treating the native fixture
as completion of the paper-specific CAP-NATIVE-ZHU2019 model.