  "document_id": "CCM-DIRECT-001",
  "date": "2026-11-19",
  "revision": "0.1",
  "standard": "CCM-WI-002 / CCM-WI-002-UL-01",
  "source_doi": "10.1016/j.est.2025.116581",
  "data_level": "published representative endpoints; not raw time histories",
  "cell": "5Ah NMC811/graphite pouch, LiFun",
  "SOC_percent": 0,
  "temperature_C_approx": 23,
  "nominal_thickness_mm_approx": 4.6,
  "measurement": "3 plate-to-plate GT2-P12 displacement sensors +/-2um; no separate dummy correction recovered",
  "target": "total compression after 90 min at nonzero 0.2MPa; not zero-load permanent strain",
  "roles": {
    "preparer": "Codex automated research/calculation",
    "test_owner": null,
    "independent_reviewer": null,
    "approver": null
  },
  "gates": [
    {
      "gate": "G0 source provenance",
      "status": "PASS_LIMITED",
      "evidence": "DOI, source section, four reported values, local hashes"
    },
    {
      "gate": "G1 raw channels/time",
      "status": "HOLD",
      "evidence": "no raw source time series for selected cell"
    },
    {
      "gate": "G2 displacement path",
      "status": "PARTIAL",
      "evidence": "plate sensors documented; cell-surface and fixture separation unresolved"
    },
    {
      "gate": "G3 calibration",
      "status": "COMPLETED_RESPONSE_ONLY",
      "evidence": "three endpoints; two-parameter OLS; no constitutive identification"
    },
    {
      "gate": "G4 withheld condition",
      "status": "UNDECIDED",
      "evidence": 0.44388753056234664,
      "unit": "percentage points",
      "acceptance_limit": null
    },
    {
      "gate": "G5 independent physical validation",
      "status": "NOT_PERFORMED"
    },
    {
      "gate": "G6 approval",
      "status": "NOT_APPROVED",
      "signature": null
    }
  ],
  "parameter_card": {
    "type": "response-surrogate-research-only",
    "coefficients": {
      "a_percent": 1.8321515892420537,
      "b_percentage_points_per_MPa": 0.8398533007334958
    },
    "validity": "same cell/fixture/SOC/T/path; preceding peak 0.2–2.5MPa; 90min at0.2MPa",
    "abaqus_material_export": false
  },
  "non_identifiable": [
    "E",
    "nu",
    "tau",
    "viscosity",
    "plastic compaction law",
    "DPC/CAP yield surface",
    "reload branch"
  ],
  "required_next_data": [
    "raw synchronized F and independent plate/cell displacement during load/unload/reload",
    "sensor calibration and fixture baseline",
    "individual reference thickness, area, uncertainty",
    "multiple rates and recovery times",
    "held-out specimen with predefined engineering tolerance"
  ]
}